58
Figure 33. Move coupling with pry bar to test alignment of auger and bearing
6.8 WEAR PLATE REMOVAL AND INSTALLATION
Note: Wear plates should be replaced when the distance between the outer edge of the wear plate and the auger screw
flighting is within 1/8 inch. In general, wear plate replacement should take place before the auger flighting shows signs
of wear.
Note: The auger screw should be replaced when the distance between the outer edge of the auger flighting and bolt
HOLE is within 1/8 inch. When the auger flighting has worn to the bolt holes, the entire auger screw will need to be
replaced (PN MX10803).
Figure 34. Worn auger wear plates in need of replacing
Содержание P Series
Страница 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Страница 2: ...2 5810 47 Avenue Olds Alberta Canada T4H 1V1 E info proallinc com P 403 335 9500 F 403 335 9560 ...
Страница 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Страница 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Страница 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Страница 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Страница 105: ... BATTERY V BATTERY V ...