13
5. TESTS AND DIAGNOSTICS
Use these tests as a guide to trouble-shoot and replace components if need be. The Commander display provides a lot
of information that can be used to diagnose potential issues. Use this information first to narrow down potential issues
before you replace or adjust components.
5.1 CANBUS SPEED SENSORS
IMPORTANT!
Speed sensor operation on the mixer is crucial to ensuring metering functions are reaching their speed set-
points and in the calculation of total volume output. There are ways to run the mixer in a “LIMP” mode when a
sensor has failed, but this should only be done in emergency circumstances.
Sensor components:
The speed sensor is made up of two main components. The
first is the sensor and the second the magnet .
The magnet is threaded into the end of rotary shaft and the
sensor measures via magnetic field the rotation of the shaft
and converts this to a pulse and RPM output.
Electrical diagnostics:
All CANBUS speed sensors can be checked for operation on
the Commander display.
Should an issue arise that points to a speed sensor not
working the first step is to check Electrical Diagnostics to
see what is active (green) and what isn’t (red) .
All speed sensors are designated by their function and the
abbreviation “ENC”, which is short for encoder.
If a function shows up as red it is either not connecting to
the CANBUS network or it isn’t physically installed (various
optional equipment).
If the sensor diagnostic is red check wiring connections to
ensure they are not loose or broken. Also, inspect
connections for corrosion, pins broken or pushed back.
A
B
C
D
C
D
A
B
Содержание P Series
Страница 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Страница 2: ...2 5810 47 Avenue Olds Alberta Canada T4H 1V1 E info proallinc com P 403 335 9500 F 403 335 9560 ...
Страница 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Страница 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Страница 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Страница 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Страница 105: ... BATTERY V BATTERY V ...