35
5.7.3 SYSTEM VOLTAGE
The system ECU and display voltage can be checked on the
Electrical Diagnostics screen and is a good indicator of truck
voltage regulation and loose or bad main power
connections.
Voltage below 9V will cause electronic devices to shutdown
and/or go into a fault condition.
Another good indicator of the Commanders set voltage is
shown on the Mixer Settings and Maintenance screen. The
Commander can be set for either 12V or 24V systems. If the
voltage setting does not show the correct voltage for the
system press the default curves set button and see if it
changes.
If it does not change, reboot the Commander display by
pressing the E-Stop and waiting 3-4 seconds and restart. Go
back to the Mixer Settings and Maintenance screen and
check the voltage setting again.
If it still reads the incorrect voltage call Proall as this may
indicate the system has been reset in the Factory Settings
and needs to be re-configured.
If the Commander system is set for the wrong voltage the
control valves will not function properly. Mixer functions
will be either really fast or really slow (may not run at all).
A
A
Содержание P Series
Страница 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Страница 2: ...2 5810 47 Avenue Olds Alberta Canada T4H 1V1 E info proallinc com P 403 335 9500 F 403 335 9560 ...
Страница 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Страница 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Страница 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Страница 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Страница 105: ... BATTERY V BATTERY V ...