Chapter 5 - System Setup
5-3
PL-5900 Series User Manual
Halt On
Designates the type of processing that will be performed when an error occurs
during the Initial Start-Up Self Test. The [All But Disk /Key] and is recommended
for most users.
[All Errors]
:
Displays all errors and stops the unit.
[No Errors]
:
Displays all errors and does not stop the unit.
[All, But Keyboard]
: Displays all errors, except for those related to
the keyboard, and stops the unit. If the User has
no keyboard connected, please use this setting.
[All, But Diskette]
:
Displays all errors, except for those related to
the disk drive (FDD), and stops the unit.
[All, But Disk/Key]
: Displays all errors, except for those related to the disk
drive (FDD) and keyboard, and then stops the unit.
Selecting IDE Primary Master or IDE Primary Slave from the Standard CMOS
Features menu brings up the following screen.
5.2.2 IDE Primary Master/IDE Primary Slave
IDE HDD Auto-Detection
Press Enter
IDE Primary Master
Auto
Access Mode
Auto
Capacity
10056 MB
Cylinder
19485
Head
16
Precomp
0
Landing Zone
19484
Sector
63
↑↓→←
:
Move Enter:/-/PU/PD:Value F10:Save ESC:Exit F1:General Help
F5:Previous Values F6:Fail-Safe Defaults F7:Optimized Defaults
CMOS Setup Utility - Copyright (C) 1984-2000 Award Software
IDE Primary Master
Item Help
Menu Level
To auto-detect the
HDD's size, head...on
this channel
IDE HDD Auto-Detection
This setting enables auto-detection of the IDE hard disk drive.
Access Mode
This setting determines the access mode of the PL's IDE hard disk drive. The
available settings are [CHS], [LBA], [Large], and [Auto]. The factory default
setting is [Auto] and is recommended for most users.
IDE Primary Master (Slave)
This setting sets the method for determining the parameter settings of the PL's IDE
hard disk drive. The available settings are [None], [Auto], and [Manual]. The
factory default setting is [Auto] and is recommended for most users.
Capacity/ Cylinder/ Head/ Precomp/ Landing Zone/ Sector
This setting determines the parameters of the PL's IDE hard disk drive. The
setting is required when the [IDE Primary Master (Slave)] is set to [Manual] and
the [Access Mode] is set to [CHS]. When the [IDE Primary Master (Slave)] is set
to [None] or [Auto], the auto-detected values will be used. Capacity is set
automaticaly.