  vides adequate air for combustion and ventilation, 

and therefore no additional make up air is required.

5.  For a ‘confined’ space or an ‘unconfined’ space in a 

building with unusually tight construction, an addition-

al source of make up air is required. Please consult an 

HVAC professional to determine the best way to supply 

make up air for this type of installation.

Important:

 Furnace room must never be in a negative 

pressure condition. Negative pressure could result in 

smoke in the room.

low Water temperature protection

It Is tHE rEspOnsIBIlIty OF tHE InstallEr tO 

prOVIdE lOW WatEr tEmpEraturE prOtECtIOn 

In tHE dEsIGn OF tHE HEat dIstrIButIOn systEm

  

The Empyre Elite XT furnace is no different than an oil 

boiler or gas boiler in that condensation of the products 

of combustion will occur if flue gases come in contact with 

a surface that is less than 140°F (60°C). With an oil or 

gas boiler the rate of fuel and consistency of the fuel is 

automatic, so if the temperature of the water in the boiler 

falls below the desired setting the burner comes on auto-

matically raising the water temperature. The Empyre Elite 

XT requires an automatic protection from low water tem-

perature because of the manual fuel feed.
Condensation (water) in the boiler tubes will cause corro-

sion and premature failure. The Empyre System Optimiz-

er, as installed in Figures 1-3, page 14, gives the Empyre 

Elite XT excellent protection from low water temperatures.

Empyre system Optimizer

The Empyre System Optimizer (ESO) is designed with a low 

loss header which includes a Danfoss VTC valve, complete 

with  a  pump  flange  and  bypass  piping.  The  Danfoss 

VTC tempering valve was selected for its simplicity and 

reliability.
The Empyre System Optimizer is mandatory on all Empyre 

Elite XT installations in order to maintain the warranty.

How the EsO and Valve Operates

 

The Empyre System Optimizer provides a constant 

circulation of water through the boiler and the Danfoss VTC 

tempering valve. Water is drawn off the low loss header by 

the building piping system and returned to that same loop 

where it mixes with the water in the low loss header. Before 

it reenters the boiler, it passes through the tempering valve. 

If the water entering the valve is too cold, the valve starts 

to slow the water returning and mixes it with water coming 

directly from the boiler. If the return water temperature 

drops below 140°F (60°C) the valve will stop this cold 

water from entering the boiler. The valve will open again 

when the  boiler water rises in temperature.

Electrical Hookup

Have a junction box with a receptacle installed in the 

back of the furnace by a qualified electrician to ensure 

all national and municipal codes are met. This is to be 

installed inside the back of the furnace on the bottom 

pan surface or up on either side. 

note:

 The junction box and receptacle installation is to 

be a dedicated receptacle to run the furnace and the 

circulating pumps. 

Water line Hookup

See Figures 1 to 3. 

Important: 

Pump must always be in lowest part of 

the water line system from the Empyre Elite XT to the 

building. Pump may be at the furnace or in the building.

note: 

The spacing between the tees must be no more 

than 4 times the diameter of the plumbing line size. 
The Empyre System Optimizer may be installed in the 

vertical position.

ImpOrtant :

the installation drawings in this manual are 

conceptual drawings only. this furnace is to 

be installed by a professional plumbing and 

heating company and qualified electrician. 

Ensure your installation is suitable for 

your application, will serve your needs and 

conforms to all local, provinicial

/

state and 

national codes.

the pro-Fab Industries warranty covers the 

Empyre Elite Xt furnace only and does not 

include anything outside of the Empyre 

Elite Xt furnace. pro-Fab Industries takes 

nO responsibility for installations. dO nOt 

modify this unit in any way. Any modification 

will void the warranty.

Содержание Empyre Elite XT

Страница 1: ...Installation and Operation Instructions Empyre Elite XT Model 100 and 200...

Страница 2: ......

Страница 3: ...tion Dimensions 11 Trench for Underground Pipes 11 Outdoor Furnace Installation 12 Outdoor Chimney Installation 12 Indoor Chimney Installation 12 Supplying Make Up Air 12 Low Water Temperature Protect...

Страница 4: ...During Heating Season 20 End of Heating Season 21 Reference 22 27 Operating the Digital Temperature Switch DTS 22 Hot Water Wood Furnace Wiring Diagram 23 How to Correct a Sticking Flapper 24 Furnace...

Страница 5: ...e Empyre Elite XT Works The Empyre Elite XT uses a process called wood gasification to produce highly efficient combustion in the furnace s dual burn chambers 1 Wood in the firebox burns from the bott...

Страница 6: ..._________ Serial No _______________________________ EMPYRE ELITE XT HYDRONIC FURNACE 15 Empyre Elite XT 100 200 702112231 or 70626288 Empyre Elite XT 100 200 no 702112231 ou no 70626288 817978R00 Mode...

Страница 7: ...running mode timer is then locked out 2 After loading CLOSE and LATCH door firmly and move LEVER to the right DO NOT operate with loading door open ASH REMOVAL DOOR ALWAYS OPEN SLOWLY 1 ALWAYS switch...

Страница 8: ...ally hazardous situation that if not avoided MAY result in minor or moderate injury if proper practices are not taken or serves as a reminder to follow appropriate safety practices Safety Decals Pleas...

Страница 9: ...PA 211 and NFPA90B Chimney must be a listed UL 103 HT or ULC S629 residential all fuel type or tile lined masonry Flue connector pipe must be made of a minimum 24 NSG black steel Special precautions a...

Страница 10: ...or Panel 13 Secondary Burn Chamber 13 A Brick Configuration No Description 13 B Insulation Board Configuration 14 Ash Tray 15 Smoke Deflector Angle 16 Latch Catch Locking Bolt Front Rear Door 17 Latch...

Страница 11: ...39 Electric Element Ports 40 Flue Cleaning Tool 41 Drain 42 Rear Lower Cover No Description 43 Right Side Panel 44 Supply Port 1 Elite XT 100 1 1 4 Elite XT 200 45 Flue Clean Out Cover 46 Probe Shiel...

Страница 12: ...rovided that a noncombustible liner such as sheet metal or masonry be placed on the floor ensuring the following areas are covered to catch stray embers Underneath the furnace At least 16 406 mm in fr...

Страница 13: ...to determine the line size necessary to meet the demands of your specific application 4 Identify each water line clearly in order to correctly locate the supply and return lines 5 Lay down 14 2 under...

Страница 14: ...Sections of stove pipe minimum 24 gauge black or blued steel may be used from the furnace to the insulated chimney Note avoid using 90 Elbows 45 is recommended A chimney cap must be installed Lining m...

Страница 15: ...ESO and Valve Operates The Empyre System Optimizer provides a constant circulation of water through the boiler and the Danfoss VTC tempering valve Water is drawn off the low loss header by the buildin...

Страница 16: ...Closely Spaced Tees See Note Empyre Elite XT Figure 2 Connect to Existing Boiler Pump Boiler Return Plate Exchanger Pump Boiler Supply Existing Boiler Return from System Pump ESO Figure 3 Empyre Elit...

Страница 17: ...arm as low as possible Side Arm Installation Figure 1 To domestic heating system Hot water in from Pro Series furnace To top of hot water tank From bottom of hot water tank Figure 2 PUMP BALL VALVE TH...

Страница 18: ...through vent opening Figure 1 9 Check water level when water temperature is 170 F 77 C and add water until level indicator shows full Maintaining Proper Water Level When the water level is low the Em...

Страница 19: ...wood when possible When using the recommended seasoned wood where the moisture content is between 19 and 25 the diameter of the wood is not that important Scenario 1 is also created when stirring a h...

Страница 20: ...out ash tray 4 Reach the ash rake to the back of the chamber and pull ash forward into the ash tray Do not scrape all of the ash into the ash tray It is recommended to leave 1 2 2 5 5 1 cm of ash cov...

Страница 21: ...nace WILL NOT operate To maintain optimal performance 1 Do not leave loading door open for extended periods of time especially when the fire is very hot 2 Do not force the loading door open beyond the...

Страница 22: ...er flues weekly A buildup in the flues and chimney will cause a poor draft and reduce efficiency 6 Check and clean the air passages in the upper loading door frame several times during the heating sea...

Страница 23: ...treatment is in the system In the event that there has been water loss through the season additional water treatment will need to be added Follow the treatment ratio on the bottle for additional gallo...

Страница 24: ...ircuit probe error Open probe error DTS Technical Data Accuracy 1 Output 16 Amp 1HP 240 Vac SPDT relay Supply voltage 115 Vac 10 Display 3 digit red DTS Programming Press SET SP text will appear on th...

Страница 25: ...range 1 White Orange Yellow Blue Blue Blue Yellow Purple White Red Orange Ground 110 volts AC 60Hz Black power line White neutral line NO NC 2 CAUTION DO NOT CONNECT THE ELECTRICAL COMPONENTS OF THIS...

Страница 26: ...ist 1 Check if furnace is being operated properly 2 Remove flapper unit check to ensure the flap seals in the closed position clean and oil How to Remove and Reinstall 1 Disconnect power 2 Remove blow...

Страница 27: ...15 cm 6 in 15 cm Log Length 24 in 61 cm 25 in 64 cm Log Diameter 6 in 15 cm 6 in 15 cm Furnace Weight excluding pallet 1 050 lb 476 kg 1 635 lb 742 kg Water Capacity 60 US Gal 227 L 112 US Gal 424 L N...

Страница 28: ...569 9 61 81 335 2 13 20 852 5 33 56 1484 5 58 45 Elite 100 Unit Dimensions 3 1 4 1 2 Not shown 0 817753 Revisions DESCRIPTION ECO Production Release 2535 REV Figure 2 Brick Layout Figure 3 Refractory...

Страница 29: ...Front Burn Chamber Elite 200 1 3 1 2 4 Elite 200 Refractory Layout ITEM NO PART NO DESCRIPTION QTY 1 816951 Insulation Fibre Board Side Burn Chamber Elite 200 6 2 816952 Insulation Fibre Board Bottom...

Страница 30: ...s air passage in the firebox floor is blocked by charcoal ash Using the ash rake always stir the firebox charcoal ash into the lower ash chamber before adding wood Limit the charcoal ash buildup and l...

Страница 31: ......

Страница 32: ...Registration and a copy of the original bill invoice must be forwarded to Pro Fab within thirty 30 days of the date of purchase to validate the warranty Issue Date February 2013 Part No 817969R01 Prin...

Отзывы: