background image

Lume n 200/S/P r o

 

 

1

 

 

Lumen200/Lumen200S 

Lumen200Pro 

 

 

 

 

 

 

User Manual v1.2

Содержание Lumen200

Страница 1: ...Lumen 200 S Pro 1 Lumen200 Lumen200S Lumen200Pro User Manual v1 2...

Страница 2: ...g Down the Lumen200 17 3 6 When to Change the Bulb 17 SECTION 4 LUMEN200S 18 4 1 Identifying your System 18 4 2 Installing your System 19 4 2 1 Installing the Bulb 19 4 2 2 Connecting to the Microscop...

Страница 3: ...stem 38 5 2 4 Connecting your Lumen200Pro to an Prior PCI Controller 39 5 3 Changing Filters in the Filter Wheel 40 5 4 Starting up the Lumen200Pro 42 5 5 Working with the Lumen200Pro 43 5 5 1 Using a...

Страница 4: ...only be connected to a power outlet which provides a protective earth ground Connect the AC power cord only to designated power sources as marked on the product Make sure the electrical cord is locat...

Страница 5: ...lways make sure the light guide is properly inserted into the collimator which is firmly attached to the microscope using the adaptor provided and into the Lumen 200 Pro before turning on the power to...

Страница 6: ...g safety instructions Definitions of Labels Warning read instructions to determine possible hazard Caution Read these operating instructions fully before use and pay particular attention to sections c...

Страница 7: ...ergy supplied is sufficient to ignite flammable substances During operation the unit must be attended at all times by a qualified operator The unit must not be left unattended while left on If an oper...

Страница 8: ...approved packaging will be accepted Ensure all items and accessories specified are present If not contact your local sales outlet Lumen 200 Standard Contents Lumen 200 Liquid Light Guide Adaptor for...

Страница 9: ...standard unit and is furnished with a manual 6 position shutter 0 10 25 50 75 and 100 The Lumen200S contains a 200 Watt Metal halide bulb which is temperature controlled The bulb is self aligning and...

Страница 10: ...the outstanding UV performance will not markedly degrade during usage we recommend that the light guide is replaced in advance of the expected lifetime of expiration Final degradation is generally cau...

Страница 11: ...eset Button Display Power Switch Manual Shutter Control Liquid Light Guide connection Liquid Light Guide Collimator Microscope Adaptor Protective cap Quartz window Fig 1 The Liquid Light Guide Fig 2 L...

Страница 12: ...ot touch the inside of the reflector of the bulb The bulb is delicate handle with care Instructions 1 Do not connect the unit to the mains supply If the Lumen200 has been previously switched on wait f...

Страница 13: ...e brown connector on the bulb into power socket in bulb housing ensure it is pushed firmly into position 5 This will orientate the bulb with the PCB and data connector socket facing upwards Fig 6 6 Lo...

Страница 14: ...s all the way into the Lamp Spring Restraints see Fig 6 Fig 6 Lamp Spring Restraint 8 The bulb is now firmly held vertically in place 9 Plug Data connector into its socket on the PCB 10 Replace the bu...

Страница 15: ...kaging and remove both plastic caps from the light guide Note It is important to remove the caps before connecting to the light guide to avoid damage on power up 3 Unscrew the connector on the front o...

Страница 16: ...e Fig 2 3 3 Starting Up the Lumen200 Warning Do not power up the Lumen200 without the light guide attached to both the Lumen200 and microscope Only power up the Lumen200 when it is installed on a leve...

Страница 17: ...3 6 When to Change the bulb The Lumen200 Bulb is installed with a timer chip which counts the hours that this specific bulb has been activated Once the bulb reaches the recommended lifetime of 2000 ho...

Страница 18: ...g 9 The Lumen200S Fig 10 The Lumen200S Side Panel Alarm reset Button Liquid Light Guide socket Display Power Switch Power Socket Power Socket Lamp On Off TTL connector Shutter connector USB Socket Fus...

Страница 19: ...ot touch the inside of the reflector of the bulb The bulb is delicate handle with care Instructions 1 Disconnect the Lumen200S from the mains supply If the Lumen200S has been previously switched on wa...

Страница 20: ...e brown connector on the bulb into power socket in bulb housing ensure it is pushed firmly into position 5 This will orientate the bulb with the PCB and data connector facing upwards 6 Locate the bott...

Страница 21: ...ll the way into the Lamp Spring Restraints see Figure 4 1e 8 The bulb is now firmly held vertically in place 9 Plug Data connector into socket on the PCB 10 Replace the bulb housing cover and replace...

Страница 22: ...aging and remove both plastic caps from the light guide Note It is important to remove the caps before connecting to the light guide to avoid damage on power up 3 Unscrew the connector on the front of...

Страница 23: ...cting your Lumen200S to a PC The Lumen200S can be controlled directly from a PC without the need of an external controller such as an OptiScan or ProScan The Lumen200S will emulate a Prior Proscan con...

Страница 24: ...24 Prior Scientific When prompted select No not at this time then click NEXT Select Install from a list or specific location advanced Fig 16 Fig 17...

Страница 25: ...Lumen 200 S Pro 25 Browse to the location of Eval232R click NEXT The Eval232R folder can be found in the SDK This can be downloaded from www prior com Contents of SDK Fig 18 Fig 19 Fig 20...

Страница 26: ...26 Prior Scientific Click Finish Fig 21...

Страница 27: ...oScan or OptiScan II system using the cables provided a It is not important which shutter ports are used on the Controller but this should be noted for use with the command set described below or for...

Страница 28: ...ximately 5 minutes for light to reach operational temperature 5 Do not power down the unit within 10 mins of power up This may reduce the effective lifetime of the bulb 4 4 Working with the Lumen200S...

Страница 29: ...umen200S with 3rd party software NOTE Intensity can only be set using the manual shutter control knob on the front of the unit 4 4 3 Using a Lumen200S with PC and OptiScan ProScan Controllers The Lume...

Страница 30: ...to result in damage to the bulb 4 6 When to Change the bulb The Lumen200S Bulb is installed with a timer chip which counts the hours that specific bulb has been activated Once the bulb reaches the rec...

Страница 31: ...roller The information end is always a line saying END This allows for the addition of extra fields of information without effecting application software Users should always read lines in until the EN...

Страница 32: ...Bulb ON For Bulb OFF UNIT 0 R Turns the bulb OFF It returns a response R on completion NOTE The bulb can only be turned on again by turning the mains switch OFF and ON again 8 S C R If shutter is not...

Страница 33: ...t is used to open close the shutter for a time t milliseconds 8 s c If shutter s is not fitted E 20 will be returned Returns status c of shutter s Shutter s Text string Prints information about shutt...

Страница 34: ...your system Alarm reset Button Liquid Light Guide socket Display Power Switch Power Socket Power Socket Lamp On Off connector Shutter Light Atttenuation connector Filter Wheel connector Fuse Sockets...

Страница 35: ...ot touch the inside of the reflector of the bulb The bulb is delicate handle with care Instructions 8 Disconnect the Lumen200Pro from the mains supply If the lumen has been previously switched on wait...

Страница 36: ...he brown connector on the bulb into power socket in bulb housing ensure it is pushed firmly into position 12 This will orientate the bulb with the PCB and data socket facing upwards 13 Locate the bott...

Страница 37: ...l the way into the Lamp Spring Restraints See Figure 29 15 The bulb is now firmly held vertically in place 16 Plug Data connector into its socket on the PCB 17 Replace the bulb housing cover and repla...

Страница 38: ...n200Pro and insert the Light guide a Ensure the light guide is fully inserted into the Lumen200Pro the light guide should be inserted by 58mm 4 Tighten the connector unit resistance is felt the light...

Страница 39: ...n II system using the cables provided a It is not important which Filter connections are used on the Controller but this should be noted for use with the command set described below and for any 3rd pa...

Страница 40: ...the screws to fix the cables in position 3 Connect the Filter Wheel to FILTER 2 using the cables provided a Tighten the screws to fix the cables in position 4 Connect lamp ON OFF to Shutter 1 connect...

Страница 41: ...hanging a Filter Equipment required Lumen200Pro Filter Prior Filter block tool flat head screw driver 1 Disconnect the Lumen from mains power and from the controller 2 Ensure the unit has been allowed...

Страница 42: ...possible This makes it easier to replace as it minimizes the stress on the internal connector 6 Turn the filter wheel until the desired filter position is reached The filter position is indicated in b...

Страница 43: ...your software 11 Replace top of unit ensuring the internal connector is aligned and replace screws 12 Reconnect controller check that the filter wheel is moving 13 Reconnect Lumen200Pro mains power St...

Страница 44: ...our Lumen200Pro to an Optiscan or Proscan system On ProscanIII system the filterwheel and light attenuation shuttering can be controlled manually via the PS3J100 interactive control center or with sof...

Страница 45: ...e bulb reaches the recommended lifetime of 2000 hours an alarm will sound on the lumen It is recommended that the bulb is changed at this point This alarm can be silenced using the button situated to...

Страница 46: ...bed below Command Arguments Response All end with cr Description a decimal number Reports status as a decimal number and gives motion status of the Filter Wheel or Shutter of the Lumen Attached to the...

Страница 47: ...s a line saying END This allows for the addition of extra fields of information without effecting application software Users should always read lines in until the END is seen A typical response is sho...

Страница 48: ...tup default FILTER w Text string Prints information about filter wheel w The information end is always a line saying END This allows for the addition of extra fields of information without effecting a...

Страница 49: ...a H performs a home routine If f is A wheel will auto home on controller startup If f is D wheel will NOT auto home on startup default FILTER w Text string Prints information about filter wheel w The...

Страница 50: ...cientific SMF w m Report the current filter wheel w maximum speed setting m SMF w m 0 Sets the current filter wheel w maximum speed to m Range is 1 to 100 Command Arguments Response All end with cr De...

Страница 51: ...e shutter to n where n can be set between 1 100 The command automatically locates LGG_SHUTTER Liquid Light Guide Shutter If n is h the shutter will perform a home routine LIGHT P n 0 Sets the filter w...

Страница 52: ...DESCRIPTION 1 NO STAGE 2 NOT IDLE 3 NO DRIVE 4 STRING PARSE 5 COMMAND NOT FOUND 6 INVALID SHUTTER 7 NO FOCUS 8 VALUE OUT OF RANGE 9 INVALID WHEEL 10 ARG1 OUT OF RANGE 11 ARG2 OUT OF RANGE 12 ARG3 OUT...

Страница 53: ...nt from bulb No Switch off unit Check bulb for damage and check data connector is securely inserted into its socket on the bulb PCB refer to Fig 7 page 15 Over Temp Fault Bulb over temperature Yes Hol...

Страница 54: ...perTerminal See ProScan OptiScan or PriorPCI manual for instructions on using HyperTerminal Send HOME command to filter wheel L200PRO only to insure it is not obstructing the optical path Confirm that...

Страница 55: ...d the recommended lifetime Check the display on the front of the Lumen200 S Pro for error message Check to see if fan vents are covered or blocked Problem Either Filter Wheel or Light Attenuator will...

Страница 56: ...bag with the box o The lamp house and rear of the unit should then be wiped down with damp paper towels or similar o Place the towels and any container used in the polythene bag and seal it o Place th...

Страница 57: ...e LM587 Filter Wheel Cable HF300 Filter Changing Tool LM589 Adapters Olympus Adaptor BX series LM10OL Olympus Adaptor IX series LM10IX Zeiss Adaptor Axio series LM10ZS Zeiss Adaptor Axiovert 25 40 ser...

Страница 58: ...ries contact Prior Scientific Instruments Limited on the telephone numbers shown below Prior Scientific Instruments Ltd Prior Scientific Inc Prior Scientific GmbH Unit 4 80 Reservoir Park Drive Wilden...

Отзывы: