![Printronix Auto ID ODV2D-V2 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/printronix/auto-id-odv2d-v2/auto-id-odv2d-v2_installation-instructions-manual_1603233029.webp)
29
1. Adjust Slope setscrew to get the indicator into the
“
green
”, as
close to “0” as possibl
e. The display on the web
page will indicate which direction to turn the screw.
Figure 32:
Web Browser “Field Calibration, Target”
Figure 33:
Slope / Tilt Dials
3) Tilt
1. For the Tilt adjustment, place the bubble level on the top of the ODV2D-V2 to make sure it is the same as
measured previously, and turn the setscrew so that it looks as straight as possible, while still keeping the dial in
the “green”.
It may be necessary to return to the Slope setscrew, turning one, then the other to get them both into
the “green”.