527-504rev
M
_EN
35
Printed in USA 12/20 © 2020
Vertical Toaster
DCFT-MCD Series
Feed new high limit switch through sleeve.
12
Remove/Replace High Limit Switch (cont.)
Apply AOS Silicon to high limit probe, and install to
platen.
13
Install high limit bracket to secure the probe to the
platen.
14
Install main platen bolts, and spacers onto unit. DO
NOT TIGHTEN THE BOLTS.
15
Install Intermediate support from platen. This will
include (2) screws, (4) spacers, and (1) heat guard.
Tip: It will be easier to install the top first, then the
bottom.
16
Reinstall (4) 3/8" nuts, (4) springs, and (4) washers on
left side of unit.
17
Tighten main platen bolts.
18
Refer to Crown Re-installation. Page 20.