Connecting Power and Data
The Bad Boy™ Spot Luminaire may be controlled by DMX512 or Ethernet. The control inputs are
located at the upper enclosure connector panel.
Figure 2-7: Data Connections
Observe the following guidelines when setting up the system:
•
The DMX512 Thru port remains active even if the luminaire is not powered up.
•
A maximum of 32 luminaires may be connected in any one DMX512 or Ethernet data link.
However, note that the maximum limit applies to the luminaire "daisy-chain" only. Your system or
console may require fewer luminaires on a single data link path. Consult your console
documentation for more information.
•
The Ethernet ports are not assigned as either In or Thru as the DMX512 ports are. Ethernet can be
connected in any configuration.
CAUTION:
The Ethernet ports are connected to an internal switch. If power is disconnected to the
luminaire, the switch will go off, therefore cutting communication to downstream luminaires.
Power is provided by the AC Line Cord Cable Assembly (25.9812.0902.5) connected to the Neutrik®
power input connector. There is no power on/off switch.
Note:
Refer to
"Comm LED Operation" on page 18
for more details about the Comm LED.
200 -240 VAC
15A Max
50 / 60 Hz
COMM
IN
DMX
THRU
ETHERNET
AC IN
CONFIG
addr
042
univ
A
TEST
LAMP
hrs
125
temp
34C
1400W
INFO
20:43
COMM
DMX
STATUS
OK
Neutrik® AC
DMX512 Input
DMX512 Thru
Power Connector
Ethernet Input/Output
Ethernet Input/Output