Download the Software
Press "Start Download" to initiate the update. You should see the luminaires immediately drop into the
startup screen and erase flash, which takes about 30 seconds. Then the new module is sent out, the
screen indicates "Loading", and when complete they will go back to the main menu and start
calibration.
If the fixture already has the update software version, it will not complete the update.
Note:
There is a bug in some versions of the boot software that causes the screen to go white during
the update process. Let the download complete before resetting the fixture, it will usually work fine.
Troubleshooting
•
If the LumLoader application does not start up, make sure the Java library is installed.
•
Make sure the network port is active before starting the application. Sometimes it takes several
seconds for the operating system to recognize the network link.
•
Make sure there is only one instance of the LumLoader application running.