DMX512 Operation

Channel Mapping

Table 3-1: DMX512 Channel Mapping 

Channel

Function

Default

Snap

Refer To Additional Table...

1

Intensity - Hi Byte

0

N

2

Intensity - Lo Byte

0

N

3

Pan - Hi Byte

127 (32767)

N

4

Pan - Lo Byte

255

N

5

Tilt - Hi Byte

127 (32767)

N

6

Tilt - Lo Byte

255

N

7

Cyan - Hi Byte

0

N

8

Cyan - Lo Byte

0

N

9

Cyan Control

0

Y

Wheel Control on p.29

10

Yellow - Hi Byte

0

N

11

Yellow - Lo Byte

0

N

12

Yellow Control

0

Y

Wheel Control on p.29

13

Magenta - Hi Byte

0

N

14

Magenta - Lo Byte

0

N

15

Magenta Control

0

Y

Wheel Control on p.29

16

Designer - Hi Byte

0

N

17

Designer - Lo Byte

0

N

18

Designer Control

0

Y

Wheel Control on p.29

19

Gobo1 - Hi Byte

0

N

20

Gobo1 - Lo Byte

0

N

21

Gobo1 Control

0

Y

Wheel Control on p.29

22

Gobo1 Index - Hi Byte

0

N

23

Gobo1 Index - Lo Byte

0

N

24

Index1 Control

0

Y

Wheel Control on p.29

25

Gobo2 - Hi Byte

0

N

26

Gobo2 - Lo Byte

0

N

27

Gobo2 Control

0

Y

Wheel Control on p.29

28

Gobo2 Index - Hi Byte

0

N

29

Gobo2 Index - Lo Byte

0

N

30

Index2 Control

0

Y

Wheel Control on p.29

31

Zoom - Hi Byte

127 (32767)

N

32

Zoom - Lo Byte

255

N

33

Edge - Hi Byte

127 (32767)

N

34

Edge - Lo Byte

255

N

35

Beam Iris - Hi Byte

255

N

36

Beam Iris - Lo Byte

255

N

37

Strobe

0

N

Strobe Control on p.31

38

Frost

0

N

39

Focus Time

255

Y

Timing Channels on p.33

40

Color Time

255

Y

Timing Channels on p.33

41

Beam Time

255

Y

Timing Channels on p.33

42

Control

0

Y

Control Channels on p.31

Содержание BAD Boy

Страница 1: ...USER MANUAL 02 9812 0001A Spot Luminaire S i i...

Страница 2: ...manual is for informational use only and is subject to change without notice Please check www prg com for latest version PRG assumes no responsibility or liability for any claims resulting from error...

Страница 3: ...ROTECTION AGAINST ELECTRICAL SHOCK FIRE EXPOSURE TO EXCESSIVE UV RADIATION AND INJURY TO PERSONS CAN BE FOUND BELOW WARNING INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST FIRE 1 PRG luminaires have bee...

Страница 4: ...nents Service and maintenance should be performed only by qualified personnel as determined by the high pressure lighting fixture manufacturer 2 Arc lamps generate intense heat Disconnect power and al...

Страница 5: ...pr cis es dans le manuel du frabricant doit tre fournies AVERTISSEMENT R GLAGE DES LAMPES 1 Chaleur intense D brancher le mat riel et laisser refroidir pendant 15 minutes avant de rallumer 2 Risque l...

Страница 6: ...een revised as follows Version Release Date Notes BASIC February 27 2009 Software version 1 0 Initial release A May 21 2009 Software version 1 1 Updated menu system spin mode values and troubleshootin...

Страница 7: ...r 2 Installation Power and Data Cabling Requirements Power 8 Data 8 DMX512 Cables 8 DMX512 Male Termination Connector 10 Ethernet Cables 10 Installation Procedure Installing Luminaire in a Hanging Con...

Страница 8: ...31 Timing Channels 32 Channel Functions 32 Timing Channel Mapping 32 Gobo Set Zero Position 36 Chapter 4 Troubleshooting and Maintenance Troubleshooting Troubleshooting Guide 38 Errors 39 Testing Tes...

Страница 9: ...TABLE OF CONTENTS 02 9812 0001A vii Appendix A Technical Specifications Bad Boy Spot Luminaire 60 Bad Boy Road Case 62 Appendix B Glossary Glossary of Terms 64...

Страница 10: ...BAD BOY SPOT LUMINAIRE USER MANUAL viii 02 9812 0001A Notes...

Страница 11: ...ation For more information regarding DMX512 systems refer to the DMX512 1990 AMX 192 Standards publication available from United States Institute for Theatre Technology Inc USITT USITT 6443 Ridings Ro...

Страница 12: ...PRG Las Vegas 6050 South Valley View Blvd Las Vegas Nevada 89118 Ph 702 942 4774 Fx 702 942 4775 PRG Los Angeles 9111 Sunland Blvd Sun Valley California 91352 Ph 818 252 2600 Fx 818 252 2620 PRG Nash...

Страница 13: ...02 9812 0001A 3 1 Description This chapter contains an overview of luminaire features and components Features Components...

Страница 14: ...Full field dimming from 0 to 100 with accurate slow speed control as well as fast bumps Quantum Color system featuring four 4 color wheels with seven discrete colors on each wheel one 1 designer whee...

Страница 15: ...wing items can be ordered from PRG Please order by PRG part number PRG P N Accessory 21 9812 0863 Bad Boy Hanging Bracket Assembly 23 9623 0177 DMX Termination Connector 25 9812 0902 5 AC Line Cord 2...

Страница 16: ...etail 200 240 VAC 15A Max 50 60 Hz COMM IN DMX THRU ETHERN ET AC IN Upper Enclosure Houses power supply ballast and provides Data In and Thru and AC power connections Also houses the Menu Touchscreen...

Страница 17: ...installing the luminaire It includes instructions for connecting power and data along with instructions for powering up the luminaire for the first time and addressing it within your system Power and...

Страница 18: ...hasing or constructing data cables it is important that not only the correct cable type be used but also quality cable to ensure a reliable DMX512 system Your cabling should meet the following USITT D...

Страница 19: ...d twisted pair Data Pin 5 2nd conduc torof2nd twisted pair Data DMX In Cable Pinout Female Conn Table 2 1 Recommended Cable Types Type Pairs Z Jacket AWG Use Temp F Belden Cables 1215A 2 150 PVC 26 IB...

Страница 20: ...nstruct your own connector you will need the following components 5 pin male XLR connector Two 1 4W 5 120 ohm resistors Note A male termination connector is also available as an accessory from PRG See...

Страница 21: ...Step 1 Unlatch and remove case lid Figure 2 2 Step 2 Remove Power Cord Safety Cables and Hanging Brackets from case Step 3 Tilt luminaire enclosure upright as shown Step 4 Install Hanging Brackets as...

Страница 22: ...nging configurations To install in truss Step 1 Roll case to mounting location as required Figure 2 4 Step 2 Using two people carefully lift luminaire into mounting position Step 3 Secure in place by...

Страница 23: ...ble MUST be used for all hanging installations and may be required by local codes Safety cable and input pigtail cable must be dressed to avoid interference with luminaire motion Square tube or round...

Страница 24: ...g position Step 1 Unlatch and remove case lid Figure 2 6 Step 2 Remove Power Cord and Safety Cables from case Step 3 Tilt case upright as shown Use grips on bottom of case to assist in tilting upward...

Страница 25: ...console documentation for more information The Ethernet ports are not assigned as either In or Thru as the DMX512 ports are Ethernet can be connected in any configuration CAUTION The Ethernet ports a...

Страница 26: ...so that they will not interfere with luminaire head or yoke movement The Ethernet ports are not assigned as either In or Thru as the DMX512 ports are Ethernet can be connected in any configuration Fi...

Страница 27: ...tion refer to Bypassing Calibration on page 18 CAUTION Before applying power be sure the luminaire is hung or positioned so that the head and yoke can move freely without restriction Refer clearances...

Страница 28: ...ion If the menu screen is touched in the center and held during startup the luminaire will present a menu that provides the option to bypass calibration This feature allows the luminaire to skip the c...

Страница 29: ...ven if power is removed Note Refer to your console operating instructions for specific information regarding its addressing requirements To program a DMX512 starting address Step 1 At Home screen pres...

Страница 30: ...el to bring up Start Douse YES NO options Figure 2 11 Starting the Lamp Step 3 Press YES to start lamp The luminaire can also be configured to power up with its lamp on or off and the maximum lamp pow...

Страница 31: ...02 9812 0001A 21 3 Operation This chapter contains instructions for using the Menu Touchscreen and controlling the luminaire by DMX512 Menu System DMX512 Operation...

Страница 32: ...tomatically return to the Home screen from a sub menu if inactive for 45 seconds The display will go into screen saver mode backlight off if inactive for five minutes The menu will automatically jump...

Страница 33: ...ion of each menu screen and its functions Pan Tilt Invert Pan Invert Tilt Swap Pan Tilt Lock Pan Lock Tilt Recalibrate ALL Pan Tilt Zoom Colors Gobos Dimmer Strobe Disable ALL Pan Tilt Zoom Wheels Mec...

Страница 34: ...if close to threshold or red if over threshold Temperature displays luminaire head temperature The temperature is shown in green if under limit yellow if close to the limit and red if over the limit P...

Страница 35: ...limit yellow if close to the limit and red if over the limit Fans displays fan status as OK if all fans are running or ERR red if any of the luminaire s fans are not running Press EXIT to return to Ho...

Страница 36: ...ting Information Screen Run Time displays current run time in hours minutes format Software Version displays software date and time stamp and software version name Fixture Hours displays total number...

Страница 37: ...o options Press EXIT to return to Home Screen Test Screen Re Cal press to bring up Recalibration Screen Re Call ALL press to bring up Re Cal ALL Yes No options Disable press to bring up Disable Screen...

Страница 38: ...igner Lo Byte 0 N 18 Designer Control 0 Y Wheel Control on p 29 19 Gobo1 Hi Byte 0 N 20 Gobo1 Lo Byte 0 N 21 Gobo1 Control 0 Y Wheel Control on p 29 22 Gobo1 Index Hi Byte 0 N 23 Gobo1 Index Lo Byte 0...

Страница 39: ...s all follow this same logic and the same control channel ranges Table 3 2 Wheel Control Range Function Notes 0 9 Continuous Continuous wheel positioning 10 19 Discrete Positioning limited to half pan...

Страница 40: ...ckwise direction Flashes from the current position to white and back as fast as possible at a random rate Flashes from the current position to white and back as fast as possible at a rate defined by t...

Страница 41: ...ld for 3 seconds followed by an immediate change to DMX 0 with out any other DMX values in between Zoom Normal is optimized for a 30 throw Zoom Short Throw is optimized for a 15 throw Gobo Set Zero al...

Страница 42: ...Timing Channels Table starting on the next page The following guidelines apply A timing value of zero is full speed A time value of 100 or 255 in DMX causes the associated parameter s to follow cue fa...

Страница 43: ...3 6 6 34 6 8 35 7 0 14 36 7 2 37 7 4 15 38 7 6 39 7 8 40 8 16 41 8 2 42 8 4 17 43 8 6 44 8 8 45 9 18 46 9 2 47 9 4 19 48 9 6 49 9 8 50 10 20 51 10 2 52 10 4 53 10 6 21 54 11 55 11 22 56 12 57 12 58 13...

Страница 44: ...38 44 139 45 55 140 45 141 45 142 46 56 143 46 144 47 57 145 47 146 47 Table 3 8 Timing Channels Continued Value DMX Seconds 147 48 58 148 48 149 49 59 150 49 151 49 152 50 60 153 50 154 50 155 51 61...

Страница 45: ...19 180 220 180 221 190 87 222 190 223 200 88 224 200 225 200 226 210 89 227 210 228 210 229 220 90 230 220 231 230 91 232 230 233 230 234 240 92 235 240 236 250 93 237 250 238 250 239 260 94 240 260 2...

Страница 46: ...tup This allows correction for a sensor that may be slightly out of position causing the gobo wheel to not be perfectly centered and therefore obstructing part of the beam in the open position To set...

Страница 47: ...ooting and Maintenance This chapter provides a basic troubleshooting guide along with procedures for testing proper handling and routine maintenance Troubleshooting Testing Software Update Equipment H...

Страница 48: ...working correctly throughout daisy chain Ensure data cables are correctly configured page 15 Ensure termination connector is installed at last luminaire in data link page 10 Lamp does not strike at p...

Страница 49: ...h specific mechanisms if any have errors It also provides a log of systems activity The Status panel operates as follows Mechanisms displays mechanism status Mechanism names will be shown in yellow if...

Страница 50: ...r Spin Error Error while sending spin command to motion processor Stop Spin Error Error while sending stop spin command to motion processor Spin Stop Timeout Spinning mechanism did not come to rest in...

Страница 51: ...options are as follows Re Cal press to bring up Recalibration Screen Re Call ALL press to bring up Re Cal ALL Yes No options Disable press to bring up Disable Screen Mech Test press to bring up Mech T...

Страница 52: ...e sensor and the other position will be off Manual Control The slider on the right side of the screen moves the mechanism through its range of travel manually Feedback The current status of the mechan...

Страница 53: ...dows does not come with the required Java run time library installed so you may need to go to the Sun website java com getjava to download Java Selecting an Ethernet Interface Connect the computer to...

Страница 54: ...the update software version it will not complete the update Note There is a bug in some versions of the boot software that causes the screen to go white during the update process Let the download com...

Страница 55: ...Ethernet To initiate the software crossload press Crossload SW at the Information screen At confirmation screen press Yes If a connected luminaire already has that software version it will do nothing...

Страница 56: ...e fill components mercury and halogen metal compounds in the lamp tubes to vaporize completely If the lamps are switched off earlier than 3 minutes the fill components are partially vaporized The inad...

Страница 57: ...replace lamp Step 1 Remove power from lamp and allow lamp to cool for at least 5 minutes Step 2 Remove power from luminaire Step 3 At rear of luminaire rotate backcap counter clockwise to remove it wi...

Страница 58: ...cing lamp Touching lamp glass with bare fingers will leave oil and cause the lamp to explode or burn out early If touched use alcohol to thoroughly clean glass Figure 4 1 Replacing the Lamp Backcap La...

Страница 59: ...1 Power up luminaire and allow to warm up for at least ten minutes Step 2 Set intensity to 100 Step 3 Position beam on a white wall at a distance of 10 to 20 Step 4 Using control console open beam si...

Страница 60: ...Gobo Wheel 2 R2 as shown in Figure 4 3 Doors are identified by a label Turn captive screw to open door CAUTION Do not touch gobos with bare fingers Wear cotton gloves or finger cots when handling Ste...

Страница 61: ...ure that the tongue of the gobo clip goes under the retaining plate under the sun gear Press and gently rotate the gobo bearing to help mesh the gobo gear to the sun gear Refer to Figure 4 5 on next p...

Страница 62: ...POT LUMINAIRE USER MANUAL 52 02 9812 0001A Figure 4 5 Gobo Positions and Alignment 2 5 7 6 OPEN 1 2 3 OPEN 1 2 3 4 5 6 7 4 1 2 3 4 5 6 7 OPEN CAUTION The gobos must be seated properly especially the g...

Страница 63: ...tton gloves or finger cots when handling Step 3 Rotate wheel until desired designer color filter is accessible Step 4 Rotate Color and Gobo 2 Wheels so that their open position lines up next to the de...

Страница 64: ...BAD BOY SPOT LUMINAIRE USER MANUAL 54 02 9812 0001A Step 7 Close head cover access door Figure 4 7 Designer Color Filter Positions 6 5 4 7 OPEN 1 2 3 EXPLODED VIEW...

Страница 65: ...from luminaire before performing any maintenance procedures Step 1 Remove power from luminaire Step 2 At each mesh cover remove two 6 32 x 1 2 PPZ screws Figure 4 8 Step 3 Remove sponge and filter Ste...

Страница 66: ...nses or reflector See next page for lens cleaning procedure Step 1 Remove power from luminaire Step 2 Using vacuum cleaner with brush nozzle or compressed air clean dust from external components If us...

Страница 67: ...aner on lenses or reflector Step 1 With luminaire powered up at TEST screen press Clean Lenses The Cleaning Lenses screen will open and lenses will be positioned so that all surfaces may be cleaned wi...

Страница 68: ...BAD BOY SPOT LUMINAIRE USER MANUAL 58 02 9812 0001A Figure 4 9 Removing Head Covers R2 Designer Wheel Head Cover R1 Head Cover Remove to Access Lenses ZOOM LENS ASSEMBLY DETAIL Lenses...

Страница 69: ...02 9812 0001A 59 APPENDIX A Technical Specifications Bad Boy Spot Luminaire Bad Boy Road Case...

Страница 70: ...ing focus during zoom changes BEAM SIZE CONTROL In addition to the zoom optics a mechanical iris provides continuous beam size control for both rapid changes and smooth timed beam angle changes EDGE C...

Страница 71: ...ECIFICATIONS 02 9812 0001A 61 A 762 mm 30 15 6 396mm 343 mm 13 5 38 6 980 mm POSITIONING Can be mounted in any orientation SPACING Hangs on 30 inch 762 mm centers WEIGHT 167 lbs 75 8 kg includes clamp...

Страница 72: ...BAD BOY SPOT LUMINAIRE USER MANUAL 62 02 9812 0001A Bad Boy Road Case EMPTY WEIGHT 90 lbs 40 8 kg LOADED WEIGHT 257 lbs 116 6 kg includes 1 one luminaire with clamps and rails 766 mm 30 15...

Страница 73: ...02 9812 0001A 63 APPENDIX B Glossary This glossary provides useful terms associated with operating Bad Boy Spot Luminaires...

Страница 74: ...to a single selectable number Channels are assigned via the patch setup Also referred to as a Control Channel Console Timing Time value in seconds or minutes applied to an entire cue Dimmer Device us...

Страница 75: ...tilt color etc Also known as Attribute Part Cue Basically a cue within a cue A portion of a cue with a time applied that is different than the cue time Patch The act of assigning a DMX512 channel to a...

Страница 76: ...ighting control protocol in the entertainment industry A console uses this protocol to control specific devices in a lighting system A DMX512 channel packet is eight bits of absolute parameter data 8...

Отзывы: