To connect power and data:
Step 1. Connect data cable (DMX512 or Ethernet) from console to appropriate input connector at
first luminaire in chain (
Figure 2-8
).
Step 2. If required, connect additional data cables from appropriate thru connectors to input
connectors of remaining luminaires in chain.
Step 3.
For DMX512 systems
: At last luminaire in chain, install male termination connector at
DMX512 THRU connector. (Luminaires and other devices on the same DMX512 chain may
not function properly without termination.) Refer to
"DMX512 Male Termination
Connector" on page 10
.
Step 4. At each luminaire, connect AC Line Cord Cable Assembly from power input source.
Step 5. Dress and secure all cables so that they will not interfere with luminaire head or yoke
movement.
* The Ethernet ports are not assigned as either In or Thru as the DMX512 ports are. Ethernet can be
connected in any configuration.
Figure 2-8: Connecting Power and Data Cables
Note:
If control data is active on both XLR and Ethernet connections, the fixture will follow the
DMX512 commands coming from the XLR.
200 -240 VAC
15AMax
50 / 60 Hz
COMM
IN
DMX
THRU
ETHERNET
ACIN
200 -240VAC
15AMax
50/ 60Hz
COMM
IN
DMX
THRU
ETHERNET
ACIN
200 -240 VAC
15AMax
50/ 60 Hz
COMM
IN
DMX
THRU
ETHERNET
ACIN
DMX512 In
Power In
Power In
Power In
Termination
Connector
DMX512 Daisy-Chain
DMX512 Thru
DMX512 Thru
200 -240 VAC
15AMax
50 / 60 Hz
COMM
IN
DMX
THRU
ETHERNET
ACIN
200 -240VAC
15AMax
50/ 60Hz
COMM
IN
DMX
THRU
ETHERNET
ACIN
200 -240 VAC
15AMax
50/ 60 Hz
COMM
IN
DMX
THRU
ETHERNET
ACIN
Ethernet
Power In
Ethernet Daisy-Chain *
Power In
Power In
Ethernet
Ethernet