Page 21
b) Entity parameters and connections of input or measurement
b.1) Voltage (V) Input:
U
i
= 30 V
U
o
= 5.4 V
I
i
= 100 mA
I
o
= 6 µA
P
i
= 750 mW
P
o
= 9 µW
C
i
= 0 nF
C
o
= 21.9 nF
L
i
= 400 µH
L
o
= 1.75 mH
Fig. 03
– V Input
b.2) Current (mA) Input:
U
i
= 30 V
U
o
= 3.5 V
I
i
= 100 mA
I
o
= 5.9 mA
P
i
= 750 mW
P
o
= 8.7 mW
C
i
= 0 nF
C
o
= 24.6 nF
L
i
= 400 µH
L
o
= 1.35 mH
Fig. 04