27
27
DL3 - (red) - Photoelectric cells contact (nC)
DL4 - (red) - Manual release security (nC)
DL5 - (red) - active programming
DL6 - (Green) - opening rod
DL7 - (red)
- Closing rod
C -
MOTOr DECELErATION CALIBrATION
this control is meant to facilitate the installer during the installation of the
system, or during possible further checks.
1 - Set DIP1 on on => the led DL5 starts to lighten.
2 - Press and keep pressed the button ProG. (now the movement is carried
out with a man present, open-stop-close-stop-open-etc.) => tHe reD LeD
DL7 switches on and the bar closes.
3 - Press and keep pressed the button ProG => tHe Green LeD DL6
switches on and the bar opens.
4 - Carry out the calibration of the deceleration speed => set the trimmer LoW
SPeeD at the minimum, than press the small button and keep it pressed =>
after one second working the deceleration is activated.
ATTENTION:
verify that the motor has enough power to move the rod both
when opening and closing. Contrariwise, increase the value set
on the trimmer until the optimal condition for working is reached.
ATTENTION:
In areas subject to particularly rigid temperatures, rotate the
trimmer 5° clockwise more than the normal value.
5 - at the end of the check set DIP1 back on oFF => theDL5 led switches off
thus signalling the exit from the check.
n.B.: During this check the enCoDer and the photoelectric cells are active.
D -
TIMEs PrOGrAMMING
THIs PrOCEDUrE Is NOrMALLY CArrIED OUT IN THE fACTOrY, BUT
IT MUsT BE rEPEATED IN CAsE YOU WIsH TO sET AN AUTOMATIC
CLOsING TIME.
1 - When the bar is entirely closed (very important for a correct learning of the
stroke).
2 - Set the micro switcher DIP 2 on on => the DL5 led will emit short flashings.
3 - Press the button ProG. => the bar opens.
4 - once the mechanic opening clamp is reached, the enCoDer stops the
motor (with encoder and time readings) and the waiting time calculation
before the automatic closing becomes active (max 5 minutes).
5 - Press the button ProG. => the waiting time calculation before the automatic
closing stops and the bar closes. In the same moment, the DL5 led stops
lightening thus signalling the exit from the machine learning procedure.
From this moment the securities or other controls of the gate will normally work
(reversals, stop, alarms, etc....).
6 - the closing of the bar will be carried out in speed mode and in the proximity
of the total closing in slow down mode.
7 - once the enCoDer calculation is over, the bar stops.
AT THE END Of THE PrOGrAMMING PUT THE DIP 2 BACK ON Off.
DUrING THE PrOGrAMMING THE sECUrITIEs ArE ACTIVE AND THEIr
INTErVENTION sTOPs THE PrOGrAMMING (THE LED DL5 WHICH
WAs LIGHTENING NOW HAs A COsTANT LIGHT ). TO rEPEAT THE
PrOGrAMMING sET THE DIP 2 ON Off), CLOsE THE BAr fOLLOWING
THE PrOCEDUrE “MOTOr DECELErATION CALIBrATION” AND
rEPEAT THE PrOGrAMMING DEsCrIBED ABOVE.
C
ONTrOL fITTINGs OPErATION
OPENING BUTTON 1 (terminals 3-6) with clock function
When the bar is stationary the button operates the opening movement. If it is
operated during the closing phase it makes the bar open again.
In Park working mode(dip 6 on) the opening of the bar to enter the parking
place is allowed.
CLOCK fUNCTION
this function is useful during the peak hours, when the vehicles traffic slows
down (e.g. entry/exit workers, emergencies in residential areas or parking
places and, temporarily, for moves).
APPLICATION MODEs
By connecting a switch and/or a clock of daily/weekly kind (instead of or in
parallel with an opening n.a. button “terminals 3-6), it is possible to open and
to keep open the automation until the switch is pressed or the clock is active.
When the automation is open, all control functions are inhibited.
If the automatic closing is active, by releasing the switch, or anyway when
the set hour expires, there will be the immediate closing of the automation,
contrariwise it will be necessary to give a command.
CLOsING BUTTON (terminals 3-7)
When the bar is open operate the closing movement.
CONTrOL sTEP BY sTEP BUTTON (terminals 3-8)
DIP5 - Off =>
Carries out a cyclic control of open-stop-close-stop-open-etc.
controls.
DIP5 - ON =>
Carries out the opening when the bar is closed. If it is operated
during the opening movement it has no effect. If it is operated
when the bar is open, it closes it. If it is operated during the
closing movement it makes it open again.
rEMOTE CONTrOL
DIP4 - Off =>
Carries out a cyclic control of open-stop-close-stop-open-etc.
controls.
DIP4 - ON =>
Carries out the opening when the bar is close. If it is operated
during the opening movement it has no effect. If it is operated
when the bar is open, it closes it. If it is operated during the
closing movement it makes it open again.
AUTOMATIC CLOsING
the pause times before the automatic closing of the bar are recorded during
the times programming.
the max. pause time is 5 minutes.
the pause time can be activated or deactivated through DIP3 (on - active).
rELEAsE fACILITATION
When the closing will be completed a reversal manoeuvre will be carried out
for a fixed time of 0,06s to facilitate the manual release.(in this phase the
enCoDer is not enabled).
fUNCTIONING WITH BLACK OUT
If TWO 12V BATTErIEs ArE CONNECTED
in series to the recharge card
positioned in the gearcase, through the dip 9 we can have the following options:
DIP 9 - Off =>
with lack of network voltage the bar opens and closes normally,
the battery state pilot light switches on thus signalling the
functioning with the battery. the functioning of the bar is
ensured up to a voltage level of about 20v, after which we
have a signalling given by the recharge card of the gearcase
which blocks the bar and makes the battery state pilot light
lighten. once the network voltage is back, the recharge card
starts charging the battery and the battery state led switches
off. It is sufficient to press the remote control (or the opening
button 1 or 2 or the step by step button ) to open the bar. When
the bar is open, give a closing command or wait the pause time
before the automatic closing => the bar starts closing. When
closed, the normal functions are reactivated.
DIP 9 - ON =>
with lack of network voltage the bar opens automatically, the
battery state led switches on and all controls are inhibited.
When the network voltage is back, the bar closes immediately
thus resetting the controls and safeties functioning.
IN CAsE NO BATTErY Is CONNECTED
, through the DIP 10 you can have
the following options:
DIP 10 - Off =>
In lack of the network voltage the bar stays still or, in case
it is moving, it stops. once the network voltage is back, it
is sufficient to press the remote control, 1 and 2 oPenInG
buttons or step by step button to open the bar. When the
bar is open, give a closing command or wait the pause time
before the automatic closing => the bar starts closing =>
When closed, the normal functions are reactivated. During the
realignment the securities are active.
DIP 10 - ON =>
at the return of the network voltage the bar closes if open, and
G
B