5.2 Rinsing the System:
1.
Once the tank is empty, it will need to be rinsed thoroughly with WATER.
2.
Unscrew the two clamps on the lid of the tank.
3.
Rinse the interior of the tank lid and hosing and clean/rinse thoroughly (in accordance with SDS
instructions).
4.
Follow the Filling and Operating procedures to fill the tank with WATER and flush the system.
5.
Operate spray gun with water to flush the liquid hosing (AI) and sprayer head. This should be done for
a minimum of 5 minutes.
6.
Follow the Emptying procedure and repeat rinsing process as needed until system is thoroughly rinsed.
7.
When the tank is empty, squeeze the spray gun trigger to allow any liquid left in the hoses and spray
gun to drain from the system.
5.3 Handle Height Adjustment:
1.
The handle height may be adjusted to the desired level for operation and storage. There are three
height settings as shown in the figure below.
FIGURE 5.3.1
Handle Base Side View
2.
To change the handle height, the pin must be removed from the current height setting by pulling
outwards from the head of the pin to pull the pin through the hole.
FIGURE 5.3.2
Handle Base Top View
3.
Repeat the process for the second pin on the opposite side of the handle.
4.
Align handle to new height, and make sure both sides are at the same level.
5.
Insert pins through the hole (flat end first) and reattach pin clamp to lock in position.
High (Vertical Position)
Medium (45° Position)
Low (Horizontal Position)
Height Adjustment Settings:
Pin Clamp
Head of pin
Pull out pin in the direction of the head
AF1
AD
AE
AF2
AF3