5.

 

Unscrew the two clamps on the lid of the tank. 

6.

 

Lift and remove the lid.  

7.

 

Carefully pour the solution into the tank. Do NOT exceed the capacity of the tank (max 2.5gal of liquid). 
Use a funnel as needed for pouring. 

8.

 

Return the lid to the tank and fasten the two clamps evenly and securely. Gradually alternate clamps 
during the tightening process to ensure a complete and even seal. 

9.

 

Close/lower the top access panel. 

 

4.3 Operating Procedure: 

1.

 

Make  sure  all  Before  Use  Checks  and  the  Filling  the  Tank  Procedures have  been  completed  and  the 
environment is safe to operate in. 

a.

 

VERIFY THE TANK DRAIN VALVE IS COMPLETELY CLOSED (HANDLE IS TO BE PERPENDICULAR 
TO THE PIPE), ALLOWING THE SOLUTION TO FLOW TO THE SPRAY GUN. 

2.

 

Plug the unit into a 120VAC GFI protected outlet, and the GFI test light will illuminate. 

3.

 

At the HydroCleaner, locate the Power Off/On switch and turn to the On position. 

4.

 

The switch will illuminate, an internal fan will start (on skinned units only), and the pump will engage to 
pressurize the equipment as needed. 

5.

 

Once the equipment is pressurized and the pump turns off, the unit is ready to begin spraying. 

a.

 

NOTE: The spray gun will release the contents of the tank into the air; be sure to appropriately 
dispense the tank contents following all SDS and safety regulations for the solution dispensing 
procedures.  

6.

 

Squeeze and hold the trigger on the spray gun to dispense the solution.  

a.

 

NOTE: During the spraying process, the pump may turn on/off as needed to maintain required 
pressure.  This is normal. 

7.

 

Release the trigger on the spray gun to stop dispensing the solution.  

8.

 

If  the  desired  spray  stream  is  not  emitted,  the  pump,  tank,  or  spray  gun  may  need  adjusted 
accordingly. 

a.

 

See the Spray Adjustments section for detailed instructions. 

9.

 

When finished spraying, release the trigger on the spray gun and turn the Power Off/On switch to Off. 

10.

 

Follow Care Instructions (section 5) after every use. 

 
4.4 Spray Adjustment:   

1.

 

Make sure all Before Use Checks, Filling the Tank, and Operating Procedures have been completed and 
the environment is safe to operate in before adjusting the spray gun. 

2.

 

Make sure the HydroCleaner is plugged in and the Power Off/On switch is in the On position. 

3.

 

The air cap on the front of the sprayer gun may be rotated to adjust the direction of the spray. Do NOT 
exceed 360° and loosen the cap. 

4.

 

The  liquid  flow  of  the  sprayer  may  be  adjusted  by  rotating  the  knob  clockwise  to  restrict  flow  and 
counterclockwise to increase flow (see Figure 4.4.1). Adjust as necessary to achieve desired spray. 

 

Содержание HydroCleaner HC-02

Страница 1: ...follow instructions may result in serious injury Carefully read all instructions before use Never spray flammable caustic acidic chlorine bleach petroleum non water based or other corrosive solutions...

Страница 2: ...T SPECIFICATIONS 5 3 SAFETY INFORMATION 6 4 OPERATION 7 4 1 BEFORE USE CHECKLIST 7 4 2 FILLING THE TANK 8 4 3 OPERATING PROCEDURE 9 4 4 SPRAY ADJUSTMENT 9 5 CARE INSTRUCTIONS 11 5 1 EMPTYING THE TANK...

Страница 3: ...ndle Base 4 FIGURE 1 1 9 Spray Gun 4 FIGURE 4 1 1 Pump Oil Cover and Air Intake 7 FIGURE 4 1 2 Bottom View of Pump Drain Plug 8 FIGURE 4 2 1 Tank Pressure Gauge 8 FIGURE 4 2 2 Tank Drain Valve Closed...

Страница 4: ...IGURE 1 1 3 Rear View w Skin L J P Q H S1 T O M K I N R FIGURE 1 1 9 Spray Gun AH AI AL AN AK AM AJ AG FIGURE 1 1 7 Side View 2 w o Skin U AB AA F H AC FIGURE 1 1 8 Handle Base AF1 AF2 AF3 AD AE FIGUR...

Страница 5: ...IN VALVE AI SPRAY GUN AIR QUICK CONNECT I TANK W DOOR SWITCH AJ SPRAY HOSING COLORED AIR J POWER OFF ON SWITCH X TANK CLAMP AK SPRAY GUN AIR FLOW ADJUST KNOB K GFI POWER CORD Y TANK PRESSURE RELIEF AL...

Страница 6: ...OT Do not use in hazardous environments or in the presence of flammable liquids gases or dust Beware of all hazards in area and in combination with sprayer contents Stop immediately if any unusual noi...

Страница 7: ...needed 5 DO NOT USE IF ANY DEFECTS ARE FOUND 6 Make sure the pump maintenance is up to date Maintenance listed below a Check the pump crankcase oil level daily before use i For HydroCleaner models wit...

Страница 8: ...the water from the system see section 5 1 Emptying the Tank 4 2 Filling the Tank 1 Make sure power is off and the HydroCleaner is unplugged 2 Lift the top access panel The tank will automatically beg...

Страница 9: ...the contents of the tank into the air be sure to appropriately dispense the tank contents following all SDS and safety regulations for the solution dispensing procedures 6 Squeeze and hold the trigge...

Страница 10: ...y vary a Before changing the tank pressure make sure the unit is powered on and the pump is finished running b When the tank pressure has stabilized adjust the regulator As per the Figure 4 4 3 below...

Страница 11: ...the top access panel 3 Place the drain hose into an appropriate collection container in accordance with SDS instructions to capture the contents from the tank Secure the hose to the container 4 Open...

Страница 12: ...in the hoses and spray gun to drain from the system 5 3 Handle Height Adjustment 1 The handle height may be adjusted to the desired level for operation and storage There are three height settings as s...

Страница 13: ...ary per SDS instructions to clean any solution that may have come in contact with the equipment while the spray gun was in use 5 Unplug the unit from the outlet and carefully store with the unit 6 Loo...

Страница 14: ...aid This warranty shall not be interpreted to render us liable for injury or damages of any kind or nature direct consequential or contingent to person or property This warranty does not extend any ex...

Отзывы: