Page
8
of
14
FIGURE 4.1.2
Bottom View
of Pump Drain Plug
iv.
Carefully remove the drain pan and safely dispose of the collected water.
v.
Close the drain valve by turning the handle 90° clockwise to be parallel with the pump
tank.
c.
On a weekly basis, unscrew the pump air intake and inspect the intake filter element. Clean or
replace as needed.
7.
Fill the tank with water and test the system per the Filling and Operating procedures. Inspect for any
leaks/clogs and any other defects in the system.
8.
If all inspections pass, empty the water from the system (see section 5.1 Emptying the Tank).
4.2 Filling the Tank:
1.
Make sure power is off and the HydroCleaner is unplugged.
2.
Lift the top access panel. The tank will automatically begin to vent.
3.
Verify the tank pressure gauge reads 0 PSI so the tank is depressurized.
Do no proceed to the next step
until depressurization is complete.
FIGURE 4.2.1
Tank
Pressure Gauge
4.
MAKE SURE THE TANK DRAIN VALVE IS COMPLETELY CLOSED (HANDLE IS TO BE PERPENDICULAR TO
THE PIPE), ALLOWING THE SOLUTION TO FLOW TO THE SPRAY GUN.
FIGURE 4.2.2
Tank Drain Valve Closed
Tank Pressure
Gauge
O
Tank drain valve in closed position.
Valve is turned clockwise to close.
Pump Drain Plug
Rotate valve counterclockwise
to open/drain.
V
S1