background image

 

 

 

 

 

Page 

14

 of 

14

  

6.  Warranty 

 
Premier Engineered Cleaning Solutions, LLC warrants each new Premier product to be free from defects in 
material and workmanship. This warranty is applicable only for the normal service life expectancy of the 
machine or components to not exceed twelve consecutive months from the date of delivery of the new Premier 
product to the original purchaser. 
 
Under no circumstance will it cover any merchandise or components thereof which, in the opinion of the 
company, has been subjected to negligent handling, misuse, alteration, an accident, or if repairs have been made 
with parts other than those obtainable through Premier Engineered Cleaning Solutions, LLC. 
 
Our obligation under this warranty shall be limited to repairing or replacing, free of charge to the original 
purchaser, any part that in our judgement shall show evidence of such defect, provided further that such part 
shall be returned within thirty (30) days from date of failure to Premier Engineered Cleaning Solutions, LLC. 
through the dealer and distributor to whom the purchase was made, transportation charges prepaid. 
 
This warranty shall not be interpreted to render us liable for injury or damages of any kind or nature, direct, 
consequential, or contingent, to person or property. This warranty does not extend any expense or loss incurred 
for labor, supplies, substitute machinery, rental or for any other reason. 
 

There are no warranties, either expressed or implied, of merchantability or fitness for particular purpose 
intended for fitness or any other reason. 

 
This warranty is subject to any existing conditions of supply which may directly affect our ability to obtain 
materials or manufacture replacement parts. 
 
Premier Engineered Cleaning Solutions, LLC. reserves the right to make improvements in design or changes in 
specifications at any time, without incurring any obligations to owners of units previously sold. 
 
No one is authorized to alter, modify, or enlarge this warranty nor the exclusions, limitations and reservations. 
 

7.  Disclaimer 

 

In no event shall our company be liable for any direct, indirect, punitive, incidental, special consequential 
damages, to property or life, whatsoever arising out of or connected with the use or misuse of our 
products. 

 
8.  Limitation of Liability 

 

In the event of claims of damage or harm to person or property, damage is limited exclusively to 
available insurance coverage, if any. 

 
 

Содержание HydroCleaner HC-02

Страница 1: ...follow instructions may result in serious injury Carefully read all instructions before use Never spray flammable caustic acidic chlorine bleach petroleum non water based or other corrosive solutions...

Страница 2: ...T SPECIFICATIONS 5 3 SAFETY INFORMATION 6 4 OPERATION 7 4 1 BEFORE USE CHECKLIST 7 4 2 FILLING THE TANK 8 4 3 OPERATING PROCEDURE 9 4 4 SPRAY ADJUSTMENT 9 5 CARE INSTRUCTIONS 11 5 1 EMPTYING THE TANK...

Страница 3: ...ndle Base 4 FIGURE 1 1 9 Spray Gun 4 FIGURE 4 1 1 Pump Oil Cover and Air Intake 7 FIGURE 4 1 2 Bottom View of Pump Drain Plug 8 FIGURE 4 2 1 Tank Pressure Gauge 8 FIGURE 4 2 2 Tank Drain Valve Closed...

Страница 4: ...IGURE 1 1 3 Rear View w Skin L J P Q H S1 T O M K I N R FIGURE 1 1 9 Spray Gun AH AI AL AN AK AM AJ AG FIGURE 1 1 7 Side View 2 w o Skin U AB AA F H AC FIGURE 1 1 8 Handle Base AF1 AF2 AF3 AD AE FIGUR...

Страница 5: ...IN VALVE AI SPRAY GUN AIR QUICK CONNECT I TANK W DOOR SWITCH AJ SPRAY HOSING COLORED AIR J POWER OFF ON SWITCH X TANK CLAMP AK SPRAY GUN AIR FLOW ADJUST KNOB K GFI POWER CORD Y TANK PRESSURE RELIEF AL...

Страница 6: ...OT Do not use in hazardous environments or in the presence of flammable liquids gases or dust Beware of all hazards in area and in combination with sprayer contents Stop immediately if any unusual noi...

Страница 7: ...needed 5 DO NOT USE IF ANY DEFECTS ARE FOUND 6 Make sure the pump maintenance is up to date Maintenance listed below a Check the pump crankcase oil level daily before use i For HydroCleaner models wit...

Страница 8: ...the water from the system see section 5 1 Emptying the Tank 4 2 Filling the Tank 1 Make sure power is off and the HydroCleaner is unplugged 2 Lift the top access panel The tank will automatically beg...

Страница 9: ...the contents of the tank into the air be sure to appropriately dispense the tank contents following all SDS and safety regulations for the solution dispensing procedures 6 Squeeze and hold the trigge...

Страница 10: ...y vary a Before changing the tank pressure make sure the unit is powered on and the pump is finished running b When the tank pressure has stabilized adjust the regulator As per the Figure 4 4 3 below...

Страница 11: ...the top access panel 3 Place the drain hose into an appropriate collection container in accordance with SDS instructions to capture the contents from the tank Secure the hose to the container 4 Open...

Страница 12: ...in the hoses and spray gun to drain from the system 5 3 Handle Height Adjustment 1 The handle height may be adjusted to the desired level for operation and storage There are three height settings as s...

Страница 13: ...ary per SDS instructions to clean any solution that may have come in contact with the equipment while the spray gun was in use 5 Unplug the unit from the outlet and carefully store with the unit 6 Loo...

Страница 14: ...aid This warranty shall not be interpreted to render us liable for injury or damages of any kind or nature direct consequential or contingent to person or property This warranty does not extend any ex...