Procedure 7.15 - Replacing All or Part of a Seat Carriage
Removing the Seat Carriage
1.
There is a heart rate cable that connects the heart rate hand grips in the seat
carriage to the hear rate cable in the seat rail. Care must be taken when removing
the seat carriage to avoid damaging the heart rate cables.
2.
Move the seat carriage to its most forward position. Carefully unsnap the water
bottle holder from the rear of the seat carriage.
3.
Remove the two screws that fasten the end cap in the seat rail. remove the end
cap. Slide the seat stop out of the seat rail. See Diagram 7.16.
Diagram 7.16 - Seat Rail End Cap and Seat Stop
4.
Remove the cable cover and disconnect the heart rate cables. See Diagram 7.17.
Water
Bottle
Holder
End Cap
Seat Stop