RBK 815 Recumbent Cycle
Page 50
Procedure 7.13 - Replacing the Lower PCA
1.
Remove the top, rear, left and right covers per procedure 7.1.
2.
Disconnect all of the wires from the lower PCA.
3.
Remove the four screws that fasten the lower PCA. Remove and discard the
lower PCA.
4.
Set the replacement lower PCA in its mounting position and fasten it with the four
screws removed in step 3.
5.
Reconnect the wiring to the lower PCA as follows: two red generator magnet
wires to M1, M2; red generator wire to M3, white generator wire to M4, black
generator wire to M5; red battery wire to M6, Black battery wire to M7; the data
cable to connector J2. See Diagram 7.14.
Diagram 7.14 - Lower PCA
6.
Replace the covers per Procedure 7.1.
Black Battery Wire
Red Battery Wire
Data Cable
Red, White Black
Generator Wires
Generator
Magnet Wires