RBK 815 Recumbent Cycle
Page 36
Procedure 7.3 - Replacing a Secondary Belt
1.
Remove the top, rear, left and right covers per procedure 7.1.
2.
Loosen but do not remove the four generator mounting bolts.
3.
Remove tension from the secondary belt by loosening the secondary belt
adjustment bolt mounted on the generator. See Diagram 7.5.
Diagram 7.5 - Secondary Belt
4.
Lift the generator, it will pivot on the rear mounting bolts, to remove the
generator’s weight from the secondary belt then remove and discard the
secondary belt.
5.
Lift the generator and place the replacement secondary belt in its mounting
position around the generator and secondary pulleys.
6.
Tension the secondary belt per Procedure 5.2.
7.
Torque the four generator mounting bolts to 100 inch pounds. Recheck the belt
tension, if it is no longer correct, slightly loosen the four generator mounting bolts
and return to step 6.
8.
Replace the covers per Procedure 7.1.
Secondary Pulley
Secondary Belt
Generator Pulley
Secondary Belt
Adj. Bolt
Generator
Mounting Bolt
Generator
Mounting Bolt
Generator
Содержание RBK 815
Страница 23: ...RBK 815 Recumbent Cycle Page 23 Diagram 6 1 Lower PCA RBK 815 TP19 TP20 J2 M6 M7 J4 M1 M2 M3 M4 M5 ...
Страница 31: ...RBK 815 Recumbent Cycle Page 31 replace the heart rate PCA to handlebar wire harness ...
Страница 40: ...RBK 815 Recumbent Cycle Page 40 14 Replace the covers per Procedure 7 1 ...
Страница 59: ...RBK 815 Recumbent Cycle Page 59 Block Diagram 8 2 RBK 815 ...