INFORMATION DISPLAY
DESCRIPTION
that PCA is replaced the hours of use would start again
from "0".
BELT RATING
(1)
(Treadmills with the ASL feature only)
Displays the belt rating from 10 (best) to 0 (worst).
Belt rating ≤ 1 replace the running belt
A belt rating of 0 or 1 will cause a blue pulsing ASL light
indicating that there is a problem with the running belt/-
deck and requires servicing or replacement.
Important
: Reset the Belt Rating after replacing with a
new running belt and deck ( hold down
QuickStart
).
MAINT COUNTER
(1)
Provides machine next maintenance due remaining
mileage or hours. Perform preventative maintenance
when the maintenance counter reaches 0.
Press/Hold the
PAUSE/RESET
key to reset the counter
(treadmills reset to 1000 miles, ellipticals reset to 250
Hrs).
Belt Maintenance
(2)
(
TRM
1
600 only)
Information used to help determine the condition of the
running belt and when the belt needs to be replaced. Belt
Maintenance provides the averaged input current values
at 6, 8, and 10 mph across 50 workouts. Measurements
are only taken when AutoStop is ON and the incline is set
to 0%.
BELT HOURS
: belt usage hours
AV-AMP-6MPH
: averaged current a 6 mph
AV-AMP-8MPH
: averaged current a 8 mph
AV-AMP-10MPH
: averaged current a 10 mph
Belt condition/disposition based on typical
AC
2
input cur-
rent values:
Normal: 8 -12 A (120Vac) / 4 - 6 A (240Vac)
Worn: ≥ 16-18 A (120Vac) / ≥ 8-9 A (240Vac)
Replace: ≥ 19 A (120Vac) / ≥ 9.5 A (240Vac)
Max Amps: 20 A (120Vac) / 10A (240Vac)
1
Treadmill
2
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 31
4 Standard Service Menus
LED Console Standard Service Menus