l
P10, P30, P30i and P31: (
Service menu (51765761)
>
MACHINE TEST
>
CROSSRAMP TEST
.
l
P62, P80, and P82: (
Service menu (51765761)
>
System Settings
>
System
Tests
>
CrossRamp Test
.
10. Verify the lift motor calibration distance has not changed:
a. Access the diagnostic
CROSSRAMP TEST
and set the incline level to 10.
b. Measure and verify the Lift Motor calibration distance remains 9" +/- 1/4" (23 cm
+/- 0.6 cm.
11.
Select
QUICKSTART
and start a manual workout. Operate the machine at the fol-
lowing conditions to verify the Stairarm and ramp incline operation. Make sure that the
Stairarms and ramp movement is smooth and that there are no unusual noises:
l
. Raise and lower the
INCLINE
from minimum to maximum range while varying
the Stairarm speed from 50 to > 150
SPM
.
l
Repeat this test for several incline cycles.
12. Reinstall the Ramp cover, the Lift Interface Plate cover, and the Front Lift cover, see
"Lift Front Cover Replacement" on page 72
"Lift Interface Plate Cover Replacement"
, and
"Covers and Panels Replacement" on page 69
.
13. Verify machine operation and return to service, see
"Operation Verification" on page 16
Note
: This procedure may have generated lift motor related error codes. Check the
error log and resolve any active error codes, clear the error log on P10, P30, P30i and
P31 consoles.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 168
6 Replacement Procedures
Lift Motor Replacement