
Battery test
where
XX.X is the measured battery voltage in VDC (nominal 12.6 - 14.6 Vdc).
VDC:
DC
1
volts
Y is the information suffix:
C: external
AC
2
charger connected.
L: Battery is low (less than 11.4 volts).
CL: Charger is connected and battery is low.
Battery Fuse
The battery inline fuse holder is part of the battery assembly cable attached to the battery pos-
itive terminal. To remove the fuse, twist the fuse holder top cap and remove.
Fuse Type: Inline 10 Amp slow blow fuse, .25" diameter
System Wire Diagram
1
Direct Current: electrical current that only flows in one direction.
2
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 224
9 Electrical Systems
System Wire Diagram