C762, C764, C764i Stairclimber
Page 64
Note:
The wires that make up the magnet cable assembly are pre-bent. When the magnet cable
assembly is installed correctly, the wires will fit naturally around the magnet assemblies.
8.
Push the blue wire connector onto the top terminal on the upper magnet coil. Push the red
wire connector onto the top terminal on the lower magnet coil. Connect the ends of the
yellow wire to the empty terminals on the magnet coils. Repeat this step if you replaced both
magnet assemblies.
9.
Check the operation of the climber as described in Section Four, then replace the covers as
described in Procedure 7.1.