Procedure 6.3 - Upper Display Does Not Illuminate
Warning
Hazardous voltages will be tested in the following procedure. Exercise extreme caution when
performing these procedures. Do not connect or disconnect any wiring, connectors or other
components with power applied to the treadmill.
1.
Disconnect the line cord from the AC wall outlet. Using an AC voltmeter, verify that the
proper AC voltage is present at the wall outlet. Nominal 120 Vac may vary between
approximately 105 Vac and 135 Vac. Nominal 240 Vac may vary between approximately
195 Vac and 245 Vac. If the AC voltage is missing or incorrect, check the AC service or
consult an electrician.
2.
Set the circuit breaker in the “off” position. Plug the treadmill’s AC line cord into the AC wall
outlet. Using an AC voltmeter, check the line cord between the blue and brown wires for the
appropriate AC voltage (as tested in step 1). If the AC voltage is missing or incorrect,
replace the line cord.
3.
Set the circuit breaker in the “on” position. Using an AC voltmeter, check between the AC
input terminals of the line filter. The AC voltage should read as in step 1. If the AC voltage is
missing or incorrect, replace the circuit breaker or the wiring between the circuit breaker and
line filter as appropriate.
4.
Using an AC voltmeter, check between the AC input terminals of the lower PCA (terminals 1
& 2 of P4). The AC voltage should read as in step 1. If the AC voltage is missing or incorrect,
replace the line filter or the wiring between the circuit breaker an lower PCA, as appropriate.
5.
Remove the fuse from the lower PCA. Using an ohmmeter, check the fuse for continuity. It
should read 1
Ω
or less. If the fuse is open or reads significantly higher than 1
Ω
replace the
fuse. If the upper display still does not illuminate continue with the next step.
6.
Using an AC voltmeter, measure between terminal 4 (White) and terminal 7 (Blue) of P3.
The AC voltage should read as in step 1. If the AC voltage is missing or incorrect, replace
the lower PCA.
7.
Using an AC voltmeter, measure between terminal 5 (Green) and terminal 6 (Yellow) of P3.
The AC voltage should read approximately 12 Vac. If the voltage is missing or incorrect,
replace the transformer.
8.
Using an AC voltmeter, measure between terminal 1 (Red) and terminal 2 (Black) of P3. The
AC voltage should read approximately 6 Vac. If the voltage is missing or incorrect, replace
the transformer.
Содержание Cardio Theater Integrated Bracket C764i
Страница 23: ...C762 C764 C764i Stairclimber Page 23 Diagram 5 3 Magnet Wiring ...
Страница 59: ...C762 C764 C764i Stairclimber Page 59 Diagram 7 6 Speed Sensor and Target Disk Assembly Speed Sensor Target ...
Страница 61: ...C762 C764 C764i Stairclimber Page 61 Diagram 7 7 Magnet Wiring ...
Страница 100: ...C762 C764 C764i Stairclimber Page 100 Wiring Diagram 8 1 C762 C764 120 Vac ...
Страница 101: ...C762 C764 C764i Stairclimber Page 101 Block Diagram 8 2 C762 C764 120 Vac ...
Страница 102: ...C762 C764 C764i Stairclimber Page 102 Wiring Diagram 8 3 C762 C764 240 Vac ...
Страница 103: ...C762 C764 C764i Stairclimber Page 103 Block Diagram 8 4 C762 C764 240 Vac ...