C762, C764, C764i Stairclimber
Page 36
3.
if a hand held signal is being accepted and a chest strap signal is not being accepted, verify
that the chest strap is good by testing it with a heart rate test receiver. If the chest strap is
good, replace the external chest strap receiver. If the heart rate test receiver does not
accept a signal from the chest strap, replace the chest strap.
4.
Replace the jumper on J10 (removed in step 1).
No hand held reading - Normal chest strap reading
5.
Set the on/off switch in the “on” position and access the diagnostic program (Procedure 2.2).
Advance to the heart rate display portion of the diagnostic program. Verify that a hand held
signal is not being accepted by firmly grasping both the right and left hand held contacts on
the handlebars. Cover as much of the contact surface area with your hands as possible
(without moving your hands), you should receive a heart rate reading within ten seconds.
6.
If a hand held heart rate signal was not received in step 5, grasp both the right and left hand
held contacts with the opposite hands, right hand on the left handlebar contacts and left
hand on the right handlebar contacts. Cover as much of the contact surface area with your
hands as possible, you should receive a heart rate reading within ten seconds. If a hand
held signal is still not being accepted, skip to step 8.
7.
If a hand held signal was accepted in step 6, the hand held contact wiring (in the handlebar)
is reversed. The end of the wire harness that connects to the hand held contacts in the
handlebar is segregated into two groups. One group has blue shrink wrap around it and the
other group has black shrink wrap around it. The “blue” group must go to the right hand
contacts and the “black” group must go to the left hand contacts. In both groups the black
wire must go to the lower contact and the red wire must go to the upper contact. I
necessary, rewire the hand held contacts as described above and test as described in step
5.
8.
Set the on/off switch in the “off” position. Refer to Diagram 6.4 for the following
measurements. With an ohmmeter measure between the “lower right contact” pin on the J1
connector and the lower right hand held heart rate contact on the handlebar. The reading
should be 1
Ω
or less. Measure between the “upper right contact” pin on the J1 connector
and the upper right hand held heart rate contact on the handlebar. The reading should be 1
Ω
or less. Measure between the “upper left contact” pin on the J1 connector and the upper
left hand held heart rate contact on the handlebar. The reading should be 1
Ω
or less.
Measure between the “lower left contact” pin on the J1 connector and the lower left hand
held heart rate contact on the handlebar. The reading should be 1
Ω
or less. If any of the
above readings are greater than 1
Ω
, replace the heart rate PCA to handlebar wire harness.
No hand held reading - No chest strap reading
9.
Set the on/off switch in the “on” position and access the diagnostic program (Procedure 2.2).
Advance to the heart rate display portion of the diagnostic program. Verify that neither a
chest strap signal or a hand held signal is being accepted with either a heart rate test
transmitter or a chest strap transmitter.
10. Check the plug/connector connections on both the heart rate PCA (J2), and upper PCA (J5).
Содержание Cardio Theater Integrated Bracket C764i
Страница 23: ...C762 C764 C764i Stairclimber Page 23 Diagram 5 3 Magnet Wiring ...
Страница 59: ...C762 C764 C764i Stairclimber Page 59 Diagram 7 6 Speed Sensor and Target Disk Assembly Speed Sensor Target ...
Страница 61: ...C762 C764 C764i Stairclimber Page 61 Diagram 7 7 Magnet Wiring ...
Страница 100: ...C762 C764 C764i Stairclimber Page 100 Wiring Diagram 8 1 C762 C764 120 Vac ...
Страница 101: ...C762 C764 C764i Stairclimber Page 101 Block Diagram 8 2 C762 C764 120 Vac ...
Страница 102: ...C762 C764 C764i Stairclimber Page 102 Wiring Diagram 8 3 C762 C764 240 Vac ...
Страница 103: ...C762 C764 C764i Stairclimber Page 103 Block Diagram 8 4 C762 C764 240 Vac ...