C762, C764, C764i Stairclimber
Page 45
Diagram 7.3 - Power Entry Wiring
Replacing the Power Cable Harness
7.
Push the power cord into the round hole on the front of the power entry module. Make sure
that the power cord connectors can reach the ground stud and circuit breaker.
8.
Place the strain relief around the power cable insulation that is next to the outside of the
power entry module.
9.
Using the pliers, press the two sections of the strain relief together while you push the strain
relief into the round hole on the front of the power entry module.
10. Connect the in-line connectors on the ends of the loose blue wires attached to the input filter
assembly and the power cord (see Diagram 7.3).
11. Connect the brown wire on the power cord to the line terminal on the circuit breaker.
12. Position the power entry module near enough to the climber to connect the lower ribbon
cable to the lower PCA.
Содержание Cardio Theater Integrated Bracket C764i
Страница 23: ...C762 C764 C764i Stairclimber Page 23 Diagram 5 3 Magnet Wiring ...
Страница 59: ...C762 C764 C764i Stairclimber Page 59 Diagram 7 6 Speed Sensor and Target Disk Assembly Speed Sensor Target ...
Страница 61: ...C762 C764 C764i Stairclimber Page 61 Diagram 7 7 Magnet Wiring ...
Страница 100: ...C762 C764 C764i Stairclimber Page 100 Wiring Diagram 8 1 C762 C764 120 Vac ...
Страница 101: ...C762 C764 C764i Stairclimber Page 101 Block Diagram 8 2 C762 C764 120 Vac ...
Страница 102: ...C762 C764 C764i Stairclimber Page 102 Wiring Diagram 8 3 C762 C764 240 Vac ...
Страница 103: ...C762 C764 C764i Stairclimber Page 103 Block Diagram 8 4 C762 C764 240 Vac ...