DIAGNOSTIC TEST
TEST DESCRIPTION
• SEC - UP/DWN command response delay between the
UPCA
1
and
LPCA
2
.
• Glitches - Momentary failures in the A/D potentiometer output. If
there are more than 50 Glitches, the lift motor should be replaced.
.
STOP KEY TEST
menu:
MACHINE TEST
>
STOP KEY TEST
(P10, P30 consoles only)
Verifies the Stop Key and E-Stop function
Test sequence steps;
1. StopKey test - Press the Stop Key
2. Lanyard ESTOP test- Pull the lanyard to trip the emergency
stop function.
3. Exit test - Press the Stop button to reset and exit test.
Notes: (1) Only used on machines that support the Active Status Light feature.
Club Settings Menu (5651565)
Service Access Code: 5651565 (see
"Service Access Codes" on page 12
)
menu: Club Settings (51765761) > DIAGS - CLUB SETTINGS
CLUB SETTINGS
DESCRIPTION
SAFETY CODE
Enabled or disabled. When enabled, a user password (xxxx) is
required to use the machine.
Factory default: disabled.
SELECT
LANGUAGE
Sets the default language for all workouts on this machine. Lan-
guage for single use workouts can also be set by the user from the
workout options.
Default: English
SET UNITS
Sets units of measure to US standard or Metric.
Range: U.S, Metric
Default: U.S.
1
Upper PCA board
2
Lower printed circuit assembly; generally this refers to the lower board. On treadmills, this is
the motor controller unit (MCU), and on self-powered units, it is the main board in the lower
section.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 22