6. Remove the two screws and remove the circuit breaker. Keep fasteners for replace-
ment installation.
7. Reference the label on the replacement circuit breaker and install the circuit breaker in
its mounting position with the LINE side of the breaker facing the input module and the
LOAD side of the circuit breaker facing the AC line filter. Install the circuit breaker using
the previously removed fasteners.
8. Install wire connections as follows for the 120
VAC
1
and 240 VAC models:
a. 120 VAC: On 120 Vac treadmills connect the blue wire from the input module to
the LINE terminal on the circuit breaker and the blue wire from the AC line filter to
the LOAD terminal on the circuit breaker.
b. 240 VAC: On 240 Vac treadmills connect the blue wire from the input module to
the upper LINE terminal on the circuit breaker and the blue wire from the AC line
filter to the upper LOAD terminal on the circuit breaker. Connect the brown wire
from the input module to the lower LINE terminal on the circuit breaker and the
brown wire from the AC line filter to the lower LOAD terminal on the circuit
breaker.
9. Set the AC input panel in its mounting position and install using the previously removed
fasteners.
10.
Plug
2
in the power cord and Switch the input power ON.
11. Verify treadmill operation per " and return to service.
.See Also
"Replacement Procedures" on page 48
1
voltage in an alternating current circuit
2
Device power cord connector or electrical cable male connector that is inserted into an elec-
trical receptacle "outlet" (also called the plug-in).
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 54
6 Replacement Procedures
Circuit Breaker Replacement