Replacing the Lower Interconnect Cable
11. Remove the rear cover per Procedure 7.19. Disconnect the interconnect cable from the
lower PCA (connector J2). See Diagram 7.3.
12. The upper and lower interconnect cables are connected at the mid-point of the main
column. Remove the mid-point column cover per Procedure 7.1.
13. Disconnect the lower interconnect cable from the mid-point connector. See Diagram 6.2.
Tape the replacement interconnect cable to the old interconnect cable at the lower PCA end
of the old interconnect cable.
14. Carefully pull the old interconnect cable out of the mid-point access hole while feeding the
new interconnect cable into the unit. When the new cable is fully into the unit, remove the
tape and discard the old interconnect cable. Connect the lower interconnect cable to the
mid-point connector and push them into the access hole.
15. Connect the new interconnect cable to the lower PCA.
16. Reconnect the red lead battery lead removed in step 1 and replace the rear cover.
17. Check the operation of the EFX as described in Section Four.