C546i Self Powered Elliptical Fitness Crosstrainer
Page 13
Procedure 3.6 - Software Uploading Procedure
This unit utilizes an upper PCA software system that is capable of on site upper PCA software
uploading (re-programming). The software upload may be accomplished with the use of a PDA
(palm device) or a laptop computer.
If a palm device is to be used it must use OS software version 3.2 or higher. Currently, we have
only tested devices manufactured by Palm, but other manufacturer’s palm devices may also
function correctly.
If a palm device is to be used, the appropriate software must be available in the palm device. A
PDA containing the appropriate software may be ordered from Precor or it may be downloaded
to the PDA from your desktop or laptop computer via the “hot sync” function. With the PDA
inserted in the hot sync cradle, download to “Precor IFP” (in field programmer) directory.
If a laptop computer is to be used, the computer’s DB9 serial port will be used for the upload.
Upload Procedure
1.
The EFX must be “powered down” before the upload procedure can be initiated. Ensure
that the EFX has not be used for a sufficient time to allow the lower PCA to completely
discharge. The light emitting diode on the lower PCA will go out when the power supply is
discharged.
2.
If the CSAFE port is in use, temporarily disconnect the RJ-45 cable from the CSAFE port. If
the CSAFE port is not in use, temporarily remove the plastic plug from the CSAFE port.
3.
Connect the PDA or computer interface cable to the CSAFE port.
4.
Select the software file to be uploaded on the palm device or computer.
5.
Start pedaling the EFX or power up using the external power supply. When the EFX “powers
up” the upload will commence. You must continue to pedal until the upload is complete,
approximately 2 minutes.
6.
Stop pedaling or disconnect the external power supply when the upload is complete, and
allow the lower PCA to completely discharge. The light emitting diode on the lower PCA will
go out when the power supply is discharged.
7.
Start pedaling the EFX, after it has been allowed to power down, the EFX will now be
operating on the newly uploaded software.
8.
Thoroughly, check the EFX’s function per Section Four.