C546i Self Powered Elliptical Fitness Crosstrainer
Page 38
Procedure 7.4
- Replacing the Upper and/or Lower Interconnect
Cables
Before you install a new interconnect cable, ensure that the interconnect cable is defective as
described in Procedure 6.1.
Procedure
1.
Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower
PCA.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Attach the wrist strap to your arm, then connect the ground lead of the wrist strap to the EFX
frame.
3.
If you are replacing the lower interconnect cable, skip to step 11.
Replacing the Upper Interconnect Cable
4.
Remove the display housing per Procedure 7.2, steps 2 to 6.
5.
The upper and lower interconnect cables are connected at the mid-point of the main
column. Remove the mid-point column cover per Procedure 7.1.
6.
Disconnect the upper interconnect cable from the mid-point connector. See Diagram 6.2.
Tape the end of the replacement interconnect cable with the to the upper end of the old
interconnect cable (display housing end).
7.
Carefully pull the old interconnect cable out of the mid-point access hole while feeding the
new interconnect cable into the unit. When the new cable is fully into the unit, remove the
tape and discard the old interconnect cable. Connect the upper interconnect cable to the
mid-point connector and push them into the access hole.
8.
Connect the upper interconnect cable to the upper PCA. Replace the display housing per
Procedure 7.2, steps 7 to 12.
9.
Remove the ground lead of the wrist strap from the EFX frame, then remove the wrist strap
from your arm.
10. Check the operation of the EFX as described in Section Four.