Large Display Temperature Meters
Instruction Manual
58
Option Card Installation in PD756
To install the Options PCB into PD756, refer to the following figures.
Figure 25. PD756 Option PCB Installation
Figure 26. PD756 Option PCB Installed
Instructions:
1. Disconnect power to the meter prior to removing the front cover.
2. Remove Display PCB and detach PCB from ribbon cable connector. Display
PCB may be removed without removing the faceplate.
3. Remove Main PCB from the base by removing four mounting screws.
4. Install Options PCB standoffs, using provided hex nuts.
5. Connect flexible cable connector J2 to J3 connector on Main PCB.
6. Install 4 mounting screws to secure Options PCB to standoffs.
7. Reassemble meter prior to applying power. Front cover may remain off until
programming is completed to allow installation of lockout jumper (see Figure
32, page 62).