Large Display Temperature Meters
Instruction Manual
33
Selecting Type of T/C or RTD (
TYPE
)
After power is applied to the meter, the display will indicate a temperature reading
which might be incorrect since the meter could be programmed for a different
type of thermocouple or RTD.
Press
ENTER
to begin scrolling through the
functions.
62f
When
type
(type) appears, press
ENTER
.
type
The meter now displays the type choices starting at the
previously programmed number; here it is type 6. The
number starts to increase up to type 10 and then goes to
type 0. Select the type number from the previous table.
Type 6
Press
ENTER
when the desired type number
appears. In this case, it is type 0 for type J T/C.
Type 0
The meter will then display
F or C
Press
ENTER
to select scale.
F or C
Press the
ACK
button to quit menu scroll and return to
indication mode. The meter is now displaying the process
temperature accurately.
72f
Select
°
F or
°
C (
f or C
)
The Digital Temperature Meter will display temperature in either
Fahrenheit or Celsius scale.
Set or change the temperature scale
Press
ENTER
to begin scrolling through the
functions.
72f
When
f or C
(
°
F or
°
C) appears, press
ENTER
.
F or C
The display will show
F
for Fahrenheit and
C
for
Celsius; they will flash alternately. Select one
when it is flashing by pressing
ENTER
.
F or C
The display will indicate the temperature in the selected
scale.
22{
Note
:
Whenever a programmed setting is changed in the basic meter, the
offset value is reset to zero and the max/min readings are reset to the
actual temperature reading. Alarm setup, set points, and 4-20 mA output
programming do not reset these settings.