Large Display Temperature Meters
Instruction Manual
57
Figure 24. PD755 Options PCB Installation
Instructions:
1. Disconnect power to the meter prior to removing the front cover.
2. Remove Display PCB and detach PCB from ribbon cable connector.
3. Remove Main PCB from the base by removing four mounting screws.
4. Install Options PCB standoffs, using provided hex nuts.
5. Connect flexible cable connector J2 to J3 connector on Main PCB.
6. Install 4 mounting screws to secure Options PCB to standoffs.
7. Reassemble meter prior to applying power. Front cover may remain off until
programming is completed to allow installation of lockout jumper (see Figure
31, page 61).