P
RO
V
U
PD6210 Analog Input Batch Controller Instruction Manual
4
Table of Figures
Figure 1: 1/8 DIN Panel Mounting ...................... 10
Figure 2: Controller Dimensions - Side View ... 11
Figure 3: Controller Dimensions - Top View .... 11
Figure 4: Transmitter Supply Voltage Selection
....................................................................... 11
Figure 5: Connector Labeling for Fully Loaded
PD6210 .......................................................... 12
Figure 6: Power Connections ............................ 12
Figure 7: Transmitters Powered by Internal
Supply ........................................................... 13
Figure 8: Transmitter Powered by Ext. Supply or
Self-Powered ................................................ 13
Figure 9: Voltage Input Connections ................ 13
Figure 10: Relay Connections ........................... 14
Figure 11: AC and DC Loads Protection .......... 14
Figure 12: Low Voltage DC Loads Protection .. 14
Figure 13: F4 Digital Input Connections ........... 15
Figure 14: 4-20 mA Output Connections .......... 15
Figure 15: Expansion Modules & DIN Rail
Mounting Kit ................................................. 16
Figure 16: External Relays Module Connections
....................................................................... 16
Figure 17: Digital I/O Module Connections ...... 16
Figure 18: Interlock Connection ........................ 16
Introduction
The P
RO
V
U
®
PD6210 is an easy-to-use batch controller ideal for simplifying independent batch
control operations where local control is preferred to expensive and expansive plant operation
systems.
Its superluminous LED digits make it easily readable in smoke, dust, fog, and, with the
optional SunBright® display, even direct sunlight.
The controller comes programmed for easy front panel start, pause, stop, and batch size (preset)
changes. The bottom display can be programmed to display rate, grand total, batch count, or
preset by cycling the Stop (F3) button. A digital input is standard.
Single and multi-stage batching is possible with up to four (4) on-board relays and four (4) external
relays with the external relay module. Each batch control relay may have a unique preclose
amount when used for multi-stage batching.
Manual start batching is default, but automatic batching with a restart after a programmed time
delay from the completion of the last batch, is also possible.
Overrun correction adjusts the closing of the batch control relays to adjust for inaccuracies from
batch to batch. This increases accuracy over time as systems wear out. The overrun correction
feature is capable of compensating for inaccuracies of up to 10% of the programmed preset value.
At least two SPDT relays are included for use in batch control or rate alarms.
The batch controller also shares all common P
RO
V
U
Series features, including an isolated 24
VDC transmitter power supply and Modbus RTU Serial communications.