PD8-6262 Explosion-Proof Dual Analog Input Flow Rate/Totalizer
Instruction Manual
31
Display Functions & Messages
The following table shows the main menu functions
and messages in the order they appear in the menu.
Display
Parameter
Action/Setting
Description
setup
Setup
Enter
Setup
menu
Input
Input
Enter
Input
selection
menu
Ch-A
*
Input
Set input type for channel
A (*or B)
nmA
4-20 mA
Set meter for 4-20 mA
input
Volt
0-10 VDC
Set meter for
10 VDC
input
total
Total
Enable/disable totalizer
functions
YES
Yes
Enable totalizer functions
No
No
Disable totalizer functions
units
Unit
Select the display
units/tags
Ch-A
*
Rate
unit
Set rate unit or tag for
channel A (*or B)
Ch-C
Math
unit
Set unit or tag for math
channel C
Tot-A
*
Total
unit
Set total unit or tag for
channel A (*or B)
Gtot-A
*
Grand total
unit
Set grand total unit or tag
for channel A (*or B)
Dec pt
Decimal
point
Set decimal point
Ch-A
*
Decimal
point
Set decimal point for
channel A (*or B or C)
Rate
*
Rate
Set rate decimal point
(*channel A and B only)
Total
*
Total
Set total decimal point
(*channel A and B only)
Gtotal
*
Grand total
Set grand total decimal
point (*channel A and B
only)
prog
Program
Enter the
Program
menu
InCAL
Input
calibration
Enter the
Input Calibration
menu
SCAL A
Scale A
Enter the
Scale
menu for
channel A
SCAl B
Scale B
Enter the
Scale
menu for
channel B
Cal A
Calibrate A
Enter the
Calibration
menu for channel A
Cal B
Calibrate B
Enter the
Calibration
menu for channel B
Inp 1
Input 1
Calibrate input 1 signal or
program input 1 value
Dis 1
Display 1
Program display 1 value
Display
Parameter
Action/Setting
Description
Inp 2
Input 2
Calibrate input 2 signal or
program input 2 value
(up to 32 points)
Dis 2
Display 2
Program display 2 value
(up to 32 points)
Error
Error
Error, calibration not
successful, check signal or
programmed value
tsetup
Total setup
Enter the
Total Setup
menu
Ch-A
*
Channel A
Setup the total for channel
A (*or B)
tbase
Time base
Program total time base
T Cf
Total
conversion
factor
Program total conversion
factor
Gt CF
Grand total
conversion
factor
Program grand total
conversion factor
treset
Total reset
Program total reset mode:
auto or manual
Ch-A
*
Channel A
Set total reset modes for
channel A (*or B)
T rst
Total reset
Program total reset mode:
auto or manual
Gt rst
Grand total
reset
Program grand total reset
mode: auto or manual
T dly
Time delay
Program automatic reset
time delay
dsplay
Display
Enter the
Display
menu
Line 1
Line 1
Assign the main display
parameter
Line 2
Line 2
Assign the second display
parameter
D Ch-A
Display
Ch-A
Assign display to
channel A
D Ch-B
Display
Ch-B
Assign display to
channel B
D Ch-C
Display
Ch-C
Assign display to
channel C (math)
D Ab
Display AB
Alternate display of
channel A & B
D AC
Display AC
Alternate display of
channel A & C
D BC
Display BC
Alternate display of
channel B & C
D AbC
Display
ABC
Alternate display of
channel A, B, & C
D t-a
Display
total A
Assign display to
channel A total
D t-b
Display
total B
Assign display to
channel B total
D gt-a
Display
grand total
A
Assign display to channel
A grand total