HOW TO DISMANTLE SYSTEM 2200

The  back  panel  of  the  module  is  detached  from  the  housing  by  way  of  a 
screwdriver as shown in picture 1 .
On a module with knobs, these may have to be removed before the PCB can be 
taken out as shown in picture 2 .
After this, the back panel can be pulled out together with the PCB, but please 
notice the position of the PCB as there is a number of different positions in the 
house . Do not pull the wires unnecessarily, instead pull the PCB, see picture 3 .
Switches and jumpers can now be moved . 
When  assembling  the  back  plate  and  housing,  please  make  sure  no  wires  are 
stuck .

Picture 1: Dismantlement of back plate 
and housing

Picture 2: Removal of knobs

Picture 3: Removal of PCBs for adjustment of DIP-switches 
and replacement of jumpers .

DECLARATION OF CONFORMITY

As manufacturer

pR electronics A/S 

hereby declares that the following product: 

Type: 2240 
Name: Transformer

is in conformity with the following directives and standards:

The EMC Directive 2004/108/EC and later amendments

EN 61326-1

  For specification of the acceptable EMC performance level, refer to the 

electrical specifications for the module .

The Low Voltage Directive 2006/95/EC and later amendments

EN 61010-1

The CE mark for compliance with the Low Voltage directive was affixed in the 

year: 

1997

Kim Rasmussen 

 

Manufacturer’s signature

Содержание 2240

Страница 1: ...е Челны 8552 20 53 41 Нижний Новгород 831 429 08 12 Новокузнецк 3843 20 46 81 Новосибирск 383 227 86 73 Омск 3812 21 46 40 Орел 4862 44 53 42 Оренбург 3532 37 68 04 Пенза 8412 22 31 16 Пермь 342 205 81 47 Ростов на Дону 863 308 18 15 Рязань 4912 46 61 64 Самара 846 206 03 16 Санкт Петербург 812 309 46 40 Саратов 845 249 38 78 Севастополь 8692 22 31 93 Симферополь 3652 67 13 56 Смоленск 4812 29 41 ...

Страница 2: ...uctions 14 Declaration of Conformity 16 How to dismantle SYSTEM 2200 17 Applications 18 Technical characteristics 18 Mounting 18 Input 18 Output 18 Electrical specifications 19 Order 20 Block diagram 20 Load diagram 21 bELASTNINGSSKEMA FOR MAx EFFEKTuDGANG ...

Страница 3: ...nual must be examined carefully Only qualified personnel technicians should install this module If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired WARNING Until the module is fixed do not connect hazardous voltages to the module The following operations should only be carried out on a disconnected module and under ESD saf...

Страница 4: ...ns educated or trained to mount operate and also troubleshoot technically correct and in accordance with safety regulations Operators being familiar with the contents of this manual adjust and operate the knobs or potentiometers during normal operation RECEIpT AND uNpACKING Unpack the module without damaging it and make sure that the manual always follows the module and is always available The pac...

Страница 5: ...please make sure no wires are stuck Picture 1 Dismantlement of back plate and housing Picture 2 Removal of knobs Picture 3 Removal of PCBs for adjustment of DIP switches and replacement of jumpers DECLARATION OF CONFORMITY As manufacturer pR electronics A S hereby declares that the following product Type 2240 Name Transformer is in conformity with the following directives and standards The EMC Dir...

Страница 6: ...ponents with 12 or 24 VAC supply voltage Transformer for stabilised DC power supplies e g type 2229 TECHNICAL CHARACTERISTICS Ring core transformer with separate 3 75 kVAC isolation voltage between primary and secondary windings The transformer is fitted with a thermal 100 C fuse Two transformers may be paralleled for higher output power The transformer is molded into the cassette and should be mo...

Страница 7: ...LOAD DIAGRAM FOR MAx pOWER OuTpuT ORDER bLOCK DIAGRAM Type Input Output 2240 115 VAC 230 VAC Special A B X Special 24 VAC 12 VAC 0 1 2 ...

Страница 8: ... 70 Мурманск 8152 59 64 93 Набережные Челны 8552 20 53 41 Нижний Новгород 831 429 08 12 Новокузнецк 3843 20 46 81 Новосибирск 383 227 86 73 Омск 3812 21 46 40 Орел 4862 44 53 42 Оренбург 3532 37 68 04 Пенза 8412 22 31 16 Пермь 342 205 81 47 Ростов на Дону 863 308 18 15 Рязань 4912 46 61 64 Самара 846 206 03 16 Санкт Петербург 812 309 46 40 Саратов 845 249 38 78 Севастополь 8692 22 31 93 Симферопол...

Отзывы: