The upper row shows the operation type; Copying for 'Copy' operation or Re-copying for 'Re-copy' or 'Recover' operation.
The Lower Row displays countdown of the numbers of balance records. Upon successful completion of the operation, the
UniRec displays the total numbers of records copied (or, re-copied) through the following message:
Records Copied
1234
Remove the Pen Drive and acknowledge the message using ENTER key. The UniRec reverts to normal RUN mode.
‘Read Chan Names’ Operation
Upon selecting ‘Read Chan Names’ operation, the UniRec opens the file named
Set.txt
for reading the user defined
channel names (refer section “File System for Read Operation”). If there is an error in opening the file or any other errors
encountered while reading the file; the UniRec displays an appropriate error message on the Upper Row of LCD display.
For various error messages and their meaning, refer Table 3.2 below.
Table : 3.2
Error Message
What it Means
Cant Open File
Unable to open the
Set.txt
file or read the file size
Cant Close File
Unable to close the file after successful reading
of channel names
Cant Read File
Unable to read the channel names from the file
In case of any of the above Error Messages, make sure that the Pen Drive is firmly inserted in the USB port and retry the
operation by acknowledging the error message through front panel ENTER key. If the error persists, replace the Pen
Drive.
However, if no error is encountered while opening, reading or closing the file, the UniRec displays the following message
after successfully reading and assigning the user defined names to the channels.
Names Assigned
USB Port Failure
In case of any failure of the USB port itself; depending upon the type of the error one of the following two messages may
be displayed on the front panel LCD.
Cant Change Baud
Cant Sync USB
Remove the Pen Drive and acknowledge the message using ENTER key. The UniRec reverts to normal RUN mode.
The UniRec needs servicing for any further Pen Drive operations.