Section 1 - Using This Manual 

This manual contains information for the NT2-210018 Touch Screen Hand Held Optical Spectrum Analyzer. This 

equipment is touchscreen capable and also has a hard keypad for operation. Note: there are a few operations only 

accessible with touchscreen operation.

This user guide is written primarily using the touchscreen operation with occasional mention of the hard key 

equivalents.

There are warnings, cautions and notes, as described below, displayed throughout this manual. Please follow all 

warnings and cautions for your safety and the protection of the equipment.

Warning

• A warning alerts to situations that could cause personal injury.

Caution

•   A caution alerts to situations that may cause damage to the equipment or produce poor testing 

conditions, resulting in inaccurate test results.

Note

• A note is a special annotation that will assist the user with operational features.

Section 2 - Safety

Section 2 of this manual is a quick start guide. Prior to using the quick start guide or operating the equipment, it is 

highly suggested the user reads all safety information first.

This product has been designed and tested in accordance with the manufacturer’s safety standards and has been 

supplied in a safe condition.

Below are warnings that must be followed by the user to ensure safe operation and to maintain the product is in a 

safe condition. Failure to follow these safety warnings, can result in damage to the instrument or harm to the user.

Warning

 Personnel should always be aware when working with fiber optic test equipment that active fibers may  

be present and therefore infrared optical energy may be present.

Warning

 Never look directly into the end of a connected fiber optic cable or fiber optic adapter of test equipment, to do 

so could expose the user to laser radiation and could result in severe personal injury.

Warning

To Prevent Fire or Shock Hazard:
• Do not install battery types other than those specified by the manufacturer
• Do not use the charger without the batteries installed
• Do not expose the battery charger to rain or excessive moisture
• Do not use the AC adapter when there are signs of damage to the enclosure or cord
• Ensure you are using the correct charger for the local line voltage
• Do not use any other charger than the one provided with this instrument
• Failure to follow these cautions may damage the equipment and void the warranty

BELDEN 

BRAND

Optical Network

Solutions

Содержание NT2-210018

Страница 1: ...NT2 210018 Optical Spectrum Analyzer User Guide A BELDEN BRAND Optical Network Solutions...

Страница 2: ...ent it is highly suggested the user reads all safety information first This product has been designed and tested in accordance with the manufacturer s safety standards and has been supplied in a safe...

Страница 3: ...ructions on setting the power level Section 3 Quick Start Guide Press the POWER button to turn on the NT2 210018 Operation The port power setting dialog will be displayed It indicates the current powe...

Страница 4: ...desired Note Touching the left hand channel number bar is a quick method to switch to the table display and touching the left most channel number bar on the table display will revert back to the grap...

Страница 5: ...d to withstand the rigors of field use and are extremely user friendly Section 5 Preparation For Use 5 1 Inspection Before shipment this instrument was inspected and found to be in perfect working ord...

Страница 6: ...battery charger to rain or excessive moisture Do not use the AC adapter when there are signs of damage to the enclosure or cord Ensure you are using the correct charger for the local line voltage Do...

Страница 7: ...zer User Guide 6176 E Molloy Rd East Syracuse NY 13057 U S A customerservice ppc online com 1 800 800 6652 1 315 431 7200 www ppc online com A BELDEN BRAND Optical Network Solutions Top Plate Fig 6 2...

Страница 8: ...er User Guide 6176 E Molloy Rd East Syracuse NY 13057 U S A customerservice ppc online com 1 800 800 6652 1 315 431 7200 www ppc online com A BELDEN BRAND Optical Network Solutions 7 2 Touch Display G...

Страница 9: ...s accessed by touching the bottom of the display or pressing the Menu button To remove the menu from the bottom of the display either select an icon touch the display above the menu or press the Menu...

Страница 10: ...h it or press Select OSA and General Settings Pages Fig 8 1 Note The Directional buttons and the Select button are not operational in the Settings screen To select a parameter to be modified touch it...

Страница 11: ...the display to toggle between high and low power Resolution The resolution may be set to 50 GHz 0 4 nm or 100 GHz 0 8 nm per channel or High and Low resolution respectively At high or low 50 or 100GHz...

Страница 12: ...the Select button on the keypad Do not use the Select icon on the file manage ment screen Enter file management again and with OSA tab highlighted move the file to be compared to the highlighted bar...

Страница 13: ...requency to match that of the system channels save and touch the Scan icon in the bottom left of the display to return to the graph screen NOTE It s important to note that this prevents reading channe...

Страница 14: ...strument s capabilities at minimum and at worst result in the need to return the NT2 210018 to the factory for expensive repairs Prior to making any connection to the unit ensure that all proper clean...

Страница 15: ...d shifts the scale accordingly This scale is also modified when Zoom is selected It shifts the number of channels as selected with the zoom feature If zoom was set to see only channels 51 60 it would...

Страница 16: ...ment To move a cursor touch anywhere between the channel number column and the cursor point column and the active cursor will snap to the channel selected To slide the cursor up and down on the displa...

Страница 17: ...n the keypad or touch the File icon on the display 10 1 File Management Display Main File Management Screen OSA Folder Fig 10 1 Configuration and Scope Folder Displays Fig 10 2 NT2 210018 Optical Spec...

Страница 18: ...down the file list until the next file to be marked is highlighted and touch Mark select again The Mark select is a toggle and to unmark a file place it in the highlighted position and touch Mark sele...

Страница 19: ...t software running touch the Upload icon and the files will transfer to the selected folder on the computer Note Config files cannot be transferred to the CertSoft software Section 11 Video Scope Oper...

Страница 20: ...mode there will be a highlight around one of the icons on the top or the bottom of the display Note Touching icons on the video scope screen will put the unit into Menu mode and activate or toggle the...

Страница 21: ...Connector Image Once the image is stable and focused use the stylus to touch the approximate center of the connector to snap the image near the center of the display and the center of the grading ring...

Страница 22: ...uick Save icon to record the information Note Marking the points of contamination should be done last just before saving the image Once the unit is re turned to live mode the markers are removed Exiti...

Страница 23: ...expose the battery charger to rain or excessive moisture Do not use the AC adapter when there are signs of damage to the enclosure or cord Ensure you are using the correct charger for the local line v...

Страница 24: ...at the port needs to be cleaned the first step is to be certain the instrument is off We suggest the use of isopropyl alcohol and foam swabs specifically designed for cleaning connectors accepting 2 5...

Страница 25: ...ions and a return authorization number RMA Section 15 Trouble Shooting Guide NT2 210018 Troubleshooting Symptom Possible Cause Solution LCD dark Power not on Press ON OFF key Batteries require recharg...

Страница 26: ...k Solutions Section 16 Version Control Through a program of continuous improvement we upgrade the features and performance of the instrument in an ongoing process The instrument firmware version is ac...

Отзывы: