Chapter 9 Options
142
Ch
ap
ter 9
75
PB200-100-2
2
≥4Ω/4kW
2
93
PB200-100-2
2
≥4Ω/5kW
2
110
PB200-100-2
3
≥4Ω/4kW
3
132
PB200-100-2
3
≥4Ω/5kW
3
160
PB200-100-2
3
≥4Ω/6kW
3
2, This table is a frequency converter 380V according to the braking unit dc working point is
670V, braking frequency is 10%, braking torque is 100% selection reference.
Inverter power
(kW)
Brake unit
Brake resistor(100% brake
torque)
Model
QTY(pc)
specification
Model
18.5
PB200-040-3
1
≥17Ω/2kW
1
22
PB200-040-3
1
≥17Ω/3kW
1
30
PB200-040-3
1
≥17Ω/3kW
1
37
PB200-040-3
1
≥17Ω/4kW
1
45
PB200-050-3
1
≥14Ω/5kW
1
55
PB200-075-3
1
≥9Ω/6kW
1
75
PB200-100-3
1
≥7Ω/8kW
1
93
PB200-100-3
1
≥7Ω/10kW
1
110
PB200-75-3
2
≥9Ω/6kW
2
132
PB200-75-3
2
≥9Ω/7kW
2
160
PB200-100-3
2
≥7Ω/9kW
2
187
PB200-100-3
2
≥7Ω/10kW
2
200
PB200-100-3
2
≥7Ω/11kW
2
220
PB200-100-3
3
≥7Ω/8kW
3
250
PB200-100-3
3
≥7Ω/9kW
3
280
PB200-100-3
3
≥7Ω/10kW
3
315
PB200-100-3
4
≥7Ω/9kW
4
355
PB200-100-3
4
≥7Ω/10kW
4
400
PB200-100-3
4
≥7Ω/11kW
4
3. This table is a frequency converter 480V according to the braking unit dc working point of
760V, braking frequency 10%, braking torque is 100% selection reference.
Inverter power
(kW)
Brake unit
Brake resistor(100% brake
torque)
Model
QTY(pc)
specification
Model
18.5
PB200-040-4
1
≥19Ω/2kW
1
22
PB200-040-4
1
≥19Ω/3kW
1
30
PB200-040-4
1
≥19Ω/3kW
1
37
PB200-040-4
1
≥19Ω/4kW
1