Chapter 5 Function parameter
84
Code
Parameter name
Setting range
Factory
default
Change
E3.03 VDI4 function selection
0 to 25
0
★
E3.04 VDI5 function selection
0 to 25
0
★
The function of virtual VDI1 to VDI5 is same as DI on the control panel, they can be
used as a multi-functional digital inputs, please refer to the introduction of F1.00 to
F1.05 for detailed settings.
E3.05 VDI active mode
Units digit
Virtual
VDI1
00000
★
Invalid
0
Valid
1
Tens digit
Virtual
VDI2
(same as
units
digit)
Hundreds digit
Virtual
VDI3
(same as
units
digit)
Thousands digit
Virtual
VDI4
(same as
units
digit)
Ten thousands
digit
Virtual
VDI5
(same as
units
digit)
E3.06 VDI status setting
Units digit
Virtual
VDI1
11111
★
The availability of
VDI depends on
the state of virtual
VDOx.
0
The availability of
VDI depends on
the state of
function code
E3.05.
1