Troubleshooting
The Powerex Whisper-Air Rotary Tooth compressor has Caution and Emergency modes programmed into the
controller.
The CAUTION modes will allow the compressor to continue to run, but will indicate what the condition is.
An emergency shut-down will occur if conditions are detected that could be damaging to the compressor unit.
Caution Conditions
Problem
Cause
Corrective Action
High Temperature
Ambient temperature too high
Room ventilation inadequate, or no circulation in room so
warm air is being recirculated.
Insufficient cooling
Cooling air inlet or outlet of unit restricted by nearby wall or
other items.
Outlet duct from unit cooling outlet too restrictive. Check
backpressure
Intercooler, oil cooler or aftercooler fins are clogged with dirt
or dust
Poor room ventilation or insufficient room ventilation
Pressure ration of 1
st
stage to 2
nd
stage is
incorrect
One or both air ends are malfunctioning and providing
insufficient compression
Other
Discharge pressure is too high. (Important for units operated at
high altitude above 3000 ft.)
Low Inlet pressure
Inlet system
Filter element is clogged
Other restriction, check hoses and silencer box. (check remote
inlet if present)
Drain Valve
Electronic drains
Outlet restricted
Malfunction of liquid sensor or solenoid
Maintenance required
Early warning
Message indicates maintenance is required within the next 200
hours
Unit can be operated with a maintenance override, Failure to
perform maintenance may void warranty