Compressor Protection
For PCCMD models, the
fault alarms output
contacts are field wired to the system control panel for
connection to the facility master alarm system.
Signs
Conditions
Status
Touch Panel
Emergency Stop
conditions
Outlet temperature of low pressure/high pressure air end or
inlet temperature of high pressure air end rises above the
emergency value set-up
Stop
Sign displayed
Oil pressure decreases below the set-up value
Motor is overloaded with the emergency value set-up
Outlet temperature sensor of low pressure/high pressure air
end or inlet temperature sensor of high pressure air end
malfunctions
Inlet pressure of high pressure air end malfunctions
Outlet pressure sensor of the compressor malfunctions
Oil pressure sensor malfunctions
Protection device is activated by overload of cooling fan motor
or oil pump motor
Emergency stop button is pressed
Caution
Conditions
Outlet temperature of low pressure/high pressure air end or
inlet temperature of high pressure air end rises above the
caution value set-up
Continue to
operate
Sign displayed
Pressure differential of an air filter is above the caution value
set-up
Pressure differential sensor of an air filter malfunctions
The total operating hours exceed the scheduled maintenance
time