WhisperAir™ Oil-free Rotary Tooth Compressor
Model Series PCC & PCCMD – 50 HP
Powerex • 150 Production Drive • Harrison, OH 45030 • USA
(T) 1.888.769.7979 • (F) 513.367.3125 • www.powerexinc.com
IN594501AV • 02/2016
Page 25 of 32
Item
Action Needed
Maintenance Intervals
(time/hours – whichever comes first)
Remarks
Every
day
Every 6
months
or 4000
Every
year or
8000
Every 2
years or
16000
Every 3
years or
24,000
Every 4
years or
32,000
Every 5
years or
40,000
Outlet check valve
Verify function (no leak
back)
●
Replace
Unload silencer
clean
●
replace
Oil seal (at gearbox
input shaft)
Check for leakage
●
Replace
Coupling Element
Check for wear debris
●
Replace early if
significant wear
debris is detected
Replace
Rubber isolation
mounts
Under compressor gear case
feet, motor mount and
cooler assembly
●
Replace if cracked or
damaged
Main Motor
Check phase to phase
resistance
●
Check phase to
ground resistance
Add Grease to main
bearings
●
Evaluate bearings with SPM
●
Replace motor if
SPM is high
Cooling fan motor
Replace
Replace assembly
Oil pump
Check for leaks
●
Replace if pump
leaks
Replace along with pump
Low-pressure/high
pressure air end,
drive shaft and gear
assembly
Replace based on SPM
●
Contact Powerex for
SPM detail