marked on the gear box. There is a small window 

in the casting of the coupling housing between the 

motor and gearbox to allow viewing of the rotating 

parts. 

2.

 

If the compressor operates in  the  opposite 

direction, the air compressor will stop due to the 

low oil pressure. At this time, alarm message will 

appear. 

3.

 

The oil pump motor and cooling fan motor are 

wired at the factory to have the correct rotation 

when the main motor is correct.  You can check the 

fan motor rotation by confirming that airflow is 

upward from the top of the unit. If the oil pump 

rotation is incorrect the pump will not generate 

any oil pressure. 

4.

 

After correct rotation is confirmed, close the back 

panels. 

Starting 

1.

 

Open the compressed air outlet valve at the outlet 

fitting. If possible open the outlet valves from the 

receiver tank as well so the unit can start without 

any compression load. 

2.

 

Close the manual drain valves (manual drain 

outlet). 

3.

 

Push “ON” on the switch. On the touch panel, push 

the “STATUS” button. As the compressor starts 

running, the operation indicator on the lower right 

will illuminate. 

During Operation 

1.

 

Close the air outlet valves at the exit of the receiver 

tank slowly. Check the display of touch panel to see 

if the outlet pressure rises. 

2.

 

When outlet pressure reaches unloading pressure, 

the compressor will be automatically switched to 

unloaded operation. After the compressor runs in 

unloaded  operation for  a total run time of 7 

minutes  the compressor will automatically stop. 

Check the status of the compressor by touching 

“STATUS” on the touch panel. 

3.

 

Open the air outlet valve slowly. Check the display 

of the touch panel to confirm the outlet pressure 

decreases. 

4.

 

When outlet pressure drops to the  loading 

pressure, the compressor will be automatically 

switched to loaded  operation.  If the compressor 

stopped automatically, it will automatically restart. 

5.

 

For VFD modes the operating sequence is similar, 

except that as the pressure increase to be near to 

the unload pressure, the main motor is slowed 

down. When pressure decreases the main motor 

speed is increased. The minimum motor speed is 

40% of nominal and if the pressure continues to 

rise under this condition, the unload operation will 

take over. If the machine remains unloaded an 

automatic shutdown will occur. 

6.

 

Operate the compressor in loaded operation for an 

hour  and check if there is  any unusual  noise, 

vibration, or oil leakage. 

7.

 

If problems are detected, shut down the unit and 

make corrections. 

Stopping 

1.

 

Push “OFF” on the control panel switch. As the 

compressor is being stopped, a message will be 

displayed on the touch panel. If the compressor 

was in loaded mode when the OFF button was 

pushed, the control will force an unload condition. 

The unit will run 30 seconds unloaded before 

stopping. 

2.

 

After the compressor is completely stopped, 

disconnect the circuit breaker. 

3.

 

Open the manual drain valve, and  empty 

condensate remaining in the separator. 

Operation 

Before Operation 

1.

 

Open the front panel and check the oil level. 

Appropriate oil level is above the center of the oil 

gauge. If the oil level is below the center of oil 

gauge, add oil before operation. 

2.

 

Open the air outlet valves. 

3.

 

Close the manual drain valves (manual drain port). 

4.

 

Close the front panel. 
 

Содержание WhisperAir PCC Series

Страница 1: ...mper PD and flows into aftercooler Ca Air cooled in the aftercooler Ca is then discharged to the drain separator for aftercooler DS2 removing the water and is delivered to the air outlet The water separated by the drain separators DS1 DS2 will be discharged through electronic drain valves EV1 EV2 When the compressor switches to unload operation the air trapped in the pulsation damper PD and the hi...

Страница 2: ...tem pressure will continue to rise and the unload control will take over Speed is maintained at 40 while unloaded When demand returns the control will increase speed and reload the compressor If the unit remains unloaded an automatic shutdown will occur after 7 minutes of total run time The system will automatically restart when pressure drops The VFD reduces wear on the intake valve parts reduces...

Страница 3: ...Oil free Rotary Tooth Compressor Model Series PCC PCCMD 50 HP Powerex 150 Production Drive Harrison OH 45030 USA T 1 888 769 7979 F 513 367 3125 www powerexinc com IN594501AV 02 2016 Page 3 of 32 Model Description ...

Страница 4: ...level of ground vibration dB Below 45 the front side of the air compressor above concrete Electrical Equipment Power supply Three phase AC rated voltage 10 60 Hz Starting method Electromagnetic Star Delta starter or VFD Compressor motor Specification Horizontal shaft D flange 3 phase totally enclosed fan cooled 2 pole type F insulation IP55 Power HP 50 Service Factor S F 1 25 Cooling fan motor Spe...

Страница 5: ... The level of ground vibration dB Below 45 the front side of the air compressor above concrete Electrical Equipment Power supply Three phase AC rated voltage 10 60 Hz Starting method Electromagnetic Star Delta starter or VFD Compressor motor Specification Horizontal shaft D flange 3 phase totally enclosed fan cooled 2 pole type F insulation IP55 Power HP 50 Service Factor S F 1 25 Cooling fan moto...

Страница 6: ...e sure the electrical supply is configured and installed according to national and local codes and has local service disconnect that can be easily accessed and operated when maintenance must be performed The Powerex unit does not include a built in power disconnect 7 Do not use this compressor as is to provide breathing air get the rest of this warning from other manuals 8 Make sure the environmen...

Страница 7: ... compressor a Instruction Manual 1 b Air outlet valve 1 c Panel key 2 Moving and Lifting Do not lift or move unit without appropriately rated equipment Be sure the unit is securely attached to lifting device used Moving with a forklift Before moving the compressor remove the front and the back panels and insert forks in the slots Make sure that the forks protrude from the other side of the frame L...

Страница 8: ...Oil free Rotary Tooth Compressor Model Series PCC PCCMD 50 HP Powerex 150 Production Drive Harrison OH 45030 USA T 1 888 769 7979 F 513 367 3125 www powerexinc com IN594501AV 02 2016 Page 8 of 32 Dimension Drawing ...

Страница 9: ...mpressor Model Series PCC PCCMD 50 HP Powerex 150 Production Drive Harrison OH 45030 USA T 1 888 769 7979 F 513 367 3125 www powerexinc com IN594501AV 02 2016 Page 9 of 32 Identification of Major Components Internal components front view ...

Страница 10: ...e Rotary Tooth Compressor Model Series PCC PCCMD 50 HP Powerex 150 Production Drive Harrison OH 45030 USA T 1 888 769 7979 F 513 367 3125 www powerexinc com IN594501AV 02 2016 Page 10 of 32 Internal components rear view ...

Страница 11: ...free Rotary Tooth Compressor Model Series PCC PCCMD 50 HP Powerex 150 Production Drive Harrison OH 45030 USA T 1 888 769 7979 F 513 367 3125 www powerexinc com IN594501AV 02 2016 Page 11 of 32 Details of Outlet Ports ...

Страница 12: ... ventilation system is contained in the condensate 2 When determining the diameter and the length of compressed air outlet pipes consider the pressure drop and allow for the possible expansion of piping network in the future Avoid sharp bends Keep pressure drop to less than 1 5 psi Refer to pipe sizing charts as needed 3 When installing branch pipes make sure the pipes are connected to the top sid...

Страница 13: ...nimum amount of ventilation required to prevent temperature rise is 16 500cfm for model PCC500 3 When installing ventilation fans consider the positions of cooling air inlet and cooling air outlet Inappropriate installation of fans will disturb the air circulation in the workplace and may affect performance of the compressor 4 The ventilation air speed at cooling air inlet must be slower than 980 ...

Страница 14: ...by the compressor enclosure Wiring Internal electrical wiring of the compressor has been completed Refer to the internal wiring circuit diagram that is packed into the control panel in the document pocket A service disconnect must be installed ahead of the compressor The service disconnect may be a circuit breaker RISK OF ELECTRICAL SHOCK Lock out and tag out all sources of energy before servicing...

Страница 15: ...terminal numbers Alarm Signals Terminals on the terminal strip provide external alarm connection points as indicated on the wiring diagram Commissioning Preparation 1 Open the center front panel and the back panels 2 Unscrew the yellow bolts on the gear case and the motor and remove the shipping supports yellow 4 3 Check the oil level on the sight glass a Appropriate oil level is above the center ...

Страница 16: ...or a total run time of 7 minutes the compressor will automatically stop Check the status of the compressor by touching STATUS on the touch panel 3 Open the air outlet valve slowly Check the display of the touch panel to confirm the outlet pressure decreases 4 When outlet pressure drops to the loading pressure the compressor will be automatically switched to loaded operation If the compressor stopp...

Страница 17: ...ker Removal At the end of service life of the compressor perform the following procedures 1 Stop the compressor and close the air outlet valves 2 Disconnect the circuit breaker and then remove the wires 3 Discharge the pressure in pipes connected to air outlet valves 4 Remove the pipes 5 Drain the oil 6 Remove the compressor Control Panel Components Automatic Control Depending on air consumption t...

Страница 18: ...ovides the function that can change the pressure band of the compressor Remote Control Remote control is the function that you can start stop the compressor remotely The setting of the compressor needs to be changed in order to activate the function Use the SET UP menu Automatic Restart after Voltage Failure Automatic restart is the function that automatically restarts the compressor after the vol...

Страница 19: ... up value Motor is overloaded with the emergency value set up Outlet temperature sensor of low pressure high pressure air end or inlet temperature sensor of high pressure air end malfunctions Inlet pressure of high pressure air end malfunctions Outlet pressure sensor of the compressor malfunctions Oil pressure sensor malfunctions Protection device is activated by overload of cooling fan motor or o...

Страница 20: ...y a history of Alarms and warnings SETUP will allow changing the operating pressures and enabling REMOTE CONTROL and AUTOMATIC RESTART The SYSTEM STATUS screen shows the condition of pressure and temperature and other operating parameters At the lower right is the operating indicator that shows whether the unit is loaded unloaded or off waiting for an automatic restart The blue rectangles are butt...

Страница 21: ...larm events You can scroll through the list after pressing SELECT ALARM The Diagnostics screen shows the status of the PLC inputs and outputs This is normally only used to troubleshoot control problems The SYSTEM SETUP screen allows you to customize the operating pressure of your compressor It also allows selection of the Auto Restart mode and operation by remote control The blue fields are button...

Страница 22: ...se screens can help you understand how your system is operating You can use the blue buttons to change the scale and zoom in or out and to move the cursor left and right The indicator field shows the value at the cursor Use the LOAD DEFAULTS button to restore the screen to its factory scale conditions The System Maintenance screen will automatically appear when maintenance is due The screen will g...

Страница 23: ... document inspections and actions may void warranty For items with check measure or clean items with replace to maintain warranty coverage or to assure future reliability Maintenance Schedule Item Action Needed Maintenance Intervals time hours whichever comes first Remarks Every day Every 6 months or 4000 Every year or 8000 Every 2 years or 16000 Every 3 years or 24 000 Every 4 years or 32 000 Eve...

Страница 24: ...ck for presence of oil in condensate discharge Investigate reason for oil content Replace element Y type strainers Clean Replace if damaged or clogged Inlet valve Switching diaphragm replacement Replace Operating diaphragm Replace Valve and spring clean and inspect Replace if damaged Valve and spring replace Slide bearing replacement Shaft Inspect Replace if damaged or worn Temperature sensors Ver...

Страница 25: ...nload silencer clean replace Oil seal at gearbox input shaft Check for leakage Replace Coupling Element Check for wear debris Replace early if significant wear debris is detected Replace Rubber isolation mounts Under compressor gear case feet motor mount and cooler assembly Replace if cracked or damaged Main Motor Check phase to phase resistance Check phase to ground resistance Add Grease to main ...

Страница 26: ...e of filter housing replace with new filter 3 Install filter cover 4 Replace panel Oil and Oil Filter Replacement 1 Run compressor until warm 2 Turn off unit lock and tag out electric power and all sources of energy 3 Connect a hose or position a pan to collect oil form oil drain valve 4 Remove plug and open oil drain valve 5 Remove oil filter and clean surfaces Apply a film of clean oil to new fi...

Страница 27: ...t cooling Cooling air inlet or outlet of unit restricted by nearby wall or other items Outlet duct from unit cooling outlet too restrictive Check backpressure Intercooler oil cooler or aftercooler fins are clogged with dirt or dust Poor room ventilation or insufficient room ventilation Pressure ration of 1st stage to 2nd stage is incorrect One or both air ends are malfunctioning and providing insu...

Страница 28: ...il pump Oil pipe or hose If there is a leak or restriction the oil pressure may be low Contact an authorized Powerex service technician to replace if necessary Oil filter If the oil filter becomes clogged the oil pressure may be low Replace the filter Oil level too low Add oil to proper level Incorrect oil If the oil type is incorrect low oil pressure may result Drain the incorrect oil and install...

Страница 29: ...lve VFD type Confirm unit goes to low speed before unload Contact an authorized Powerex technician to adjust settings or replace VFD Compressor unit runs will not load Pressure not low enough to reach load setting Check settings and actual pressure correct as needed Air leak on signal line to inlet valve Contact an authorized Powerex service technician to repair or replace air signal lines Diaphra...

Страница 30: ...e is high during load operation Failure of high pressure air end Verify the condensate separator and automatic drain is working Water intake into high pressure air end will damage compressor Contact an authorized Powerex technician to replace malfunctioning air end and separator components Mist in Compressor discharge air Condensate drain lines restricted Eliminate restrictions assure that lines r...

Страница 31: ...rranty Powerex warrants and represents all Products shall be free from Defects for the first thirty 30 months from the date of shipment by Powerex or twenty four 24 months from the documented date of startup or eight thousand 8 000 hours of use whichever occurs first During such warranty period Powerex shall be fully liable for all Defects in the Products the Product Defects i e all costs of repai...

Страница 32: ...ulations and be sure that the Product installation and use will comply with them Claims Any non warranty claims pertaining to the Products must be filed with Powerex within 6 months of the invoice date or they will not be honored Prices discounts and terms are subject to change without notice or as stipulated in specific Product quotations Powerex shall not be liable for any delay or failure arisi...

Отзывы: