background image

Page 7  — English

USE ONLY THIS SIZE EXTENSION CORD WHEN USING 
THIS PRODUCT:

Cord Length

Wire Size (A.W.G.)

  25 ft.

14 

  50 ft.

12

100 ft.

Not Allowed

NOTE: 

A.W.G. = American Wire Gauge

WARNING:

Keep the extension cord clear of the working area. 
Position the cord so that it will not get caught on  
lumber, tools, or other obstructions while you are working 
with a power tool. Failure to do so can result in serious  
personal injury.

WARNING:

Check extension cords before each use. If damaged 
replace immediately. Never use the product with a  
damaged cord since touching the damaged area could 
cause electrical shock resulting in serious injury.

GROUND FAULT CIRCUIT INTERRUPTER

See Figure 2.

This unit is equipped with a Ground Fault Circuit Interrupter 
(GFCI), which guards against the hazards of ground fault 
currents. An  example of ground fault current is the current 
that would flow through a person who is using an appliance 
with faulty insulation and, at the same time, is in contact 
with an electrical ground such as a plumbing fixture, wet 
floor, or earth.

GFCI plugs do not protect against short circuits, overloads, 
or shocks.

NOTE: 

To ensure readiness for use, press the reset button 

each time you connect the pressure washer to the power 
supply. 
The GFCI plug can be tested with the TEST and RESET 
buttons.

To test:

 

Press the TEST button. You will hear a “click” sound and 
the red LED light will go out.

 

To restore power, press the RESET button. The LED light 
will illuminate to indicate power has been restored.

Perform this test monthly to ensure proper operation of the 
GFCI.

 

To reduce the risk of electric shock the supervi-
sory circuit must be operated before an appliance is 
plugged into any receptacle on the device.

DOUBLE INSULATION

Double insulation is a concept in safety in electric power 
tools, which eliminates the need for the usual three-
wire grounded power cord. All exposed metal parts are  
isolated from the internal metal motor components with 
protecting insulation. Double insulated products do not need 
to be grounded.

WARNING:

The double insulated system is  intended to protect the 
user from shock resulting from a break in the product’s 
internal insulation. Observe all normal safety precautions 
to avoid electrical shock.

NOTE:

 Servicing of a product with double insulation requires 

extreme care and knowledge of the system and should be 
performed only by a qualified service technician. For service, 
we suggest you return the product to your nearest authorized 
service center for repair. Always use original factory replace-
ment parts when servicing.

ELECTRICAL CONNECTION

This product has a precision-built electric motor. It should 
be connected to a 

power supply that is 120 volts, AC only 

(normal household current), 60 Hz. 

Do not operate this 

product on direct current (DC). A substantial voltage drop 
will cause a loss of power and the motor will overheat. If 
the product does not operate when plugged into an outlet, 
double-check the power supply.

EXTENSION CORDS

When using a power tool at a considerable distance from 
a power source, be sure to use an extension cord that has 
the capacity to handle the current the product will draw. An  
undersized cord will cause a drop in line voltage, possibly 
resulting in overheating, loss of power, and/or circuit breaker 
or GFCI tripping. Use the chart to determine the minimum wire 
size required in an extension cord. Only round jacketed cords 
listed by Underwriter’s Laboratories (UL) should be used.
When working outdoors with a product, use an extension 
cord that is designed for outside use. This type of cord is 
designated with “WA” or “W” on the cord’s jacket.
Before using any extension cord, inspect it for loose or  
exposed wires and cut or worn insulation.
It is possible to tie the extension cord and power cord in a 
knot to prevent them from becoming disconnected during 
use. Make a knot, then connect the plug end of the power 
cord into the receptacle end of the extension cord. This 
method can also be used to tie two extension cords together.

ELECTRICAL

Содержание PS14120

Страница 1: ...or s manual before using this product ADVERTENCIA Para reducir el riesgo de lesiones el usuario debe leer y comprender el manual del operador antes de usar este producto TABLE OF CONTENTS Important Sa...

Страница 2: ...See this fold out section for all of the figures referenced in the operator s manual Consulte esta secci n desplegable para ver todas las figuras a las que se hace referencia en el manual del operado...

Страница 3: ...On off switch interruptor de encendido apagado H Nozzles boquillas I Lower handle mango inferior J Electrical cord with GFCI plug cord n del mango con tomacorriente GFCI K Soap tank cap tapa del dep...

Страница 4: ...h pressure hose manguera de alta presi n Fig 7 Fig 9 A Water outlet salida de agua B Collar casquillo A Water intake entrada de agua B Screen cedazo C Garden hose manguera de jard n Fig 10 Fig 8 A A B...

Страница 5: ...te A B C D D E F F E A Straightened paper clip clip para papel abieto B Nozzle boquilla Fig 16 Fig 17 Fig 18 A B A Hook and loop strap correa de gancho y lazada B Electrical cord with GFCI plug cord n...

Страница 6: ...A DOUBLE INSULATED APPLIANCE In a double insulated product two systems of insulation are provided instead of grounding No grounding means is provided on a double insulated product nor should a means...

Страница 7: ...s wire or string which can be thrown or become entangled in the machine Do not use product if switch does not turn it off Have switch replaced by an authorized service center Avoid dangerous environme...

Страница 8: ...uently and use them to instruct other users If you loan someone this product loan them these instructions also Do not use acids alkalines solvents flammable material bleaches or industrial grade solut...

Страница 9: ...ates a potential personal injury hazard Read Operator s Manual To reduce the risk of injury user must read and understand operator s manual before using this product Eye Protection Always wear eye pro...

Страница 10: ...o operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per second W Watt Power Alternating Current Type of current no No...

Страница 11: ...re isolated from the internal metal motor components with protectinginsulation Doubleinsulatedproductsdonotneed to be grounded WARNING The double insulated system is intended to protect the user from...

Страница 12: ...assembly n Carefully remove the product and any accessories from the box Make sure that all items listed in the packing list are included NOTE This tool is heavy To avoid back injury lift with your le...

Страница 13: ...h can cause the hose to leak during use n Pull on the hose to be certain it is properly secured CONNECTING THE GARDEN HOSE TO THE PRESSURE WASHER See Figure 8 NOTICE Always observe all local regulatio...

Страница 14: ...quipment etc Always test in an inconspicuous area first STARTING AND STOPPING THE PRESSURE WASHER See Figure 9 NOTICE Do not run the pressure washer without water supply connected and turned on as thi...

Страница 15: ...Refer to the Nozzle Selection Guide for more informa tion about which nozzle to choose WARNING NEVER remove nozzles without first turning off the mo tor relieving the water pressure in the trigger han...

Страница 16: ...lled during the filling process make sure the unit is cleaned and dried before proceeding n Install the soap nozzle on the spray wand n Start the pressure washer and spray the detergent on a dry surfa...

Страница 17: ...uthorized service center in order to avoid a safety hazard PUMP LUBRICATION The pump on this product was lubricated with a sufficient amount of high grade lubricant for the life of the unit under norm...

Страница 18: ...trap to secure the cord in place n Disconnect both the high pressure hose and the garden hose from the pump n Tilt the unit as shown to allow any remaining water in the pump to drain from the water in...

Страница 19: ...inlet filter is clogged or dirty Provide adequate water flow Check connections and or replace wand Clean nozzle Contact authorized service center Squeeze trigger on spray wand to remove air from line...

Страница 20: ...Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instruc tions and recommendations of the Company as set forth in the Product s operator s m...

Страница 21: ...TO DOBLE En un producto con aislamiento doble se proporcionan dos sistemasdeaislamientoenlugardelaconexi natierra Elhecho de que no se proporcione conexi n a tierra en un producto con aislamientodoble...

Страница 22: ...hasta no verla completamente detenida Conserve el motor limpio de c sped hojas o grasa a fin de reducir el riesgo de incendio Siga las recomendaciones del fabricante para lograr la carga descarga tra...

Страница 23: ...eden serpeligrosossiseutilizanindebidamente Nuncadirija el chorro a personas animales dispositivos el ctricos ni a la m quina misma Mantenga alejado el motor de materiales inflamables y de otros mater...

Страница 24: ...el riesgo de lesiones el usuario debe leer y comprender el manual del operador antes de usar este producto Protecci n ocular Siempre p ngase protecci n ocular con protecci n lateral con la marca de c...

Страница 25: ...r utilizar mejor y de manera m s segura la herramienta S MBOLO NOMBRE DENOMINACI N EXPLICACI N V Voltios Voltaje A Amperios Corriente Hz Hertz Frecuencia ciclos por segundo W Watts Potencia Corriente...

Страница 26: ...n a tierra Todas las partes met licas expuestas est n aisladas de los componentes met licos internos del motor por medio de aislamiento de protecci n No es necesario conectar a tierra las productos c...

Страница 27: ...cuidadosamente de la caja la herramienta y los accesorios Aseg rese de que est n presentes todos los art culos enumerados en la lista de empaquetado NOTA Esta herramienta es pesada Para evitar sufrir...

Страница 28: ...ar que la manguera pierda durante su uso n Tire de la manguera para asegurarse de que est debidamente asegurada C MO CONECTAR UNA MANGUERA DE JARD N A LA LAVADORA DE PRESI N Vea la figura 8 AVISO Siem...

Страница 29: ...rea poco notoria ENCENDIDO Y APAGADO DE LA LAVADORA DE PRESI N Vea la figura 9 AVISO No encienda la lavadora a presi n si no hay un suministro de agua conectado y encendido dado que esto podr a da ar...

Страница 30: ...jor boquilla para el trabajo Vea la Gu a de selecci n de boquillasparaobtenerm sinformaci nsobrequ boquillautilizar ADVERTENCIA NUNCA quite las boquillas sin antes apagar el motor liberar la presi n d...

Страница 31: ...ducen p rdidas de detergente durante el proceso de llenado aseg rese de limpiar y secar la unidad antes de proceder n Instale la boquilla para jab n del tubo rociador n Apague la lavadora de presi n y...

Страница 32: ...vicio autorizado deben cambiar el cord n de corriente en caso de que sea necesario para evitar peligros LUBRICACI N DE LA BOMBA Labombadeestaherramientaest nlubricadosconsuficiente cantidad de aceite...

Страница 33: ...n el correa de gancho y lazada para fijar el cord n en su lugar n Desconecte tanto la alta presi n y de baja presi n conexi ns de agua n Incline la unidad como se muestra para permitir que cualquier r...

Страница 34: ...rada de agua est tapado o sucio Suministre un flujo de agua adecuado Verifique las conexiones y o reemplace el tubo Limpie la boquilla Comun quese con un centro de servicio autorizado Oprima el gatill...

Страница 35: ...ta presi n mango del gatillo boquilla La garant a queda anulada si el cliente no instala mantiene o utiliza el producto respetando las instrucciones y las recomendaciones de la Compa a seg n se expres...

Страница 36: ...formation when you call or visit A replacement parts list is also available online REPAIR PARTS The item manufacturing and serial numbers of this product are found on a plate or label attached to the...

Отзывы: