25
3.
Power Assist Mode
And now the other load adds and the current increases to 11A. This is where Power
Assist function is needed!
(ATS ON + AC CHARGER OFF + INVERTER ON + Power Assist Mode ON)
As soon as the load reduces to less than 5A, any current that is left over will be used to
recharge the battery.
Battery
Shore Power
Load
ATS ON
AC IN
AC OUT
6A
5A
B2-05=5A
11A
90A
Solar
Charger
Solar Panel
or
5A
4.
“INVERTER Mode” Repeat
When the battery voltage is higher than B2-12 voltage value and longer than second
time set in B2-15, inverter mode takes priority to supply voltage to AC OUT again for
load consumption.
Battery
Shore Power
Ready
Load
ATS OFF
AC IN
AC OUT
3A
5A
B2-05=5A
3A
45A
Solar
Charger
Solar Panel
or
Содержание PM-1500SI-12X