2.
Power Control Mode (a)
In this example:
All AC loads are off, with the “Stackable Inverter” constant B2-05=5A (AC IN Current
Limit),
the AC CHARGER will not take more than 5A with limits to battery charge current to
75A.
3. Power Control Mode (b)
Now some small loads are switched on and load increase to 3A. Only 5-3=2A is left to
charge the batteries and charge current is reduced to about 30A.
※
Note: Shore current is automatically limited to 5A and the AC input circuit
breaker will not trip!
Battery
Shore Power
M ax 5A
Load
ATS ON
AC IN
AC OUT
5A
5A
0A
75A
5A
B2-05=5A